FMA6500 Series flow controllers allow one to program, record, and analyze flow rates of various gases with a computer via an RS485 interface (optional RS232 is available).
Made in USA. brand OMEGA, model FMA6500
International delivery to United Arab Emirates, Kuwait, Qatar, Saudi Arabia, Saudi Arabia, Bahrain, Oman and other Middle Eastern countries.
Our warehouses are located in UAE.
Retail price from $2,185.80
Available
Only the best I&C brands
Our company is a UAE supplier of control and measuring instruments from well-known world brands
Discounts for organisations
We sell high-tech equipment at best prices. We provide really advantageous conditions for partners
Fast delivery across the Middle East
Supply to United Arab Emirates, Kuwait, Qatar, Saudi Arabia, Bahrain, Oman and other countries
Professional advice on device selection
Our specialists are ready to advise you on any technical question. We can find an analogue of any device
Microprocessor driven digital flow controllers allow one to program, record, and analyze flow rates of various gases with a computer via an RS485 interface (optional RS232 is available). Controllers can be programmed for various control functions including flow setpoint, totalizer, stop totalizer, read totalizer, totalizer from preset flow, stop at preset total, auto zero, and more.
Principles of Operation
Metered gases are divided into two laminar flow paths, one through the primary flow conduit, and the other through a capillary sensor tube. Both flow conduits are designed to ensure laminar flows and, therefore, the ratio of their flow rates is constant. Two precision temperature sensing windings on the sensor tube are heated, and when flow takes place, gas carries heat from the upstream to the downstream windings. The resultant temperature differential is proportional to the change in resistance of the sensor windings. A Wheatstone bridge design is used to monitor the temperature dependent resistance gradient on the sensor windings which is linearly proportional to the instantaneous rate of flow. The output of the Wheatstone bridge is converted to digital format with a 12 Bit ADC (analog to digital converter). An on-board microprocessor and nonvolatile memory store all calibration factors and directly control a proportional electromagnetic valve. The digital closed loop control system continuously compares the mass flow output with the selected flow rate. Deviations from the setpoint are corrected by compensating valve adjustments, with PID algorithm thus maintaining the desired flow parameters with a high degree of accuracy. Output signals of 0 to 5 Vdc or 4 to 20 mA are generated indicating mass molecular based flow rates of the metered gas.
Interface
The digital interface operates via RS485 (optional RS232) and provides access to applicable internal data including FLOW SETPOINT, ACTUAL FLOW, ZERO ADJUSTMENTS, and LINEARIZATION TABLE ADJUSTMENTS. The analog interface provides 0 to 5 Vdc, 0 to 10 Vdc and 4 to 20 mA inputs and outputs.
Auto Zero
The FMA6500 automatically nulls the sensor zero offset whenever the flow setpoint is below 2% of full scale. To accommodate this feature the control valve must fully close under that condition. Provisions are made to either disable, force or store the current auto zero via digital commands.
Totalizer
The firmware for the FMA6500 provides functions to register total gas quantity. The total mass of gas is calculated by integrating the actual gas flow rate with respect to time. Digital interface commands are provided to: SET the totalizer to ZERO; START /STOP totalizing the flow; READ the totalizer; START the totalizer at a preset flow STOP the flow at a preset total.
Multi-Gas Calibration
The FMA6500 is capable of storing primary calibration data for up to 10 gases. This feature allows the same FMA6500ST to be calibrated for multiple gases while maintaining the rated accuracy on each.
Conversion Factors
Conversion factors for up to 256 gases are stored in the FMA6500. Conversion factors may be applied to any of the ten gas calibrations via digital interface commands.
Flow Alarms
High and Low gas flow ALARM limits are programmed using the digital interface. Alarm conditions are reported via the digital interface or can activate the contact closure outputs.
Programmable Flow
OMEGA software supports programmable flow modes, allowing execution of custom programming of up to ten steps. Various flow configurations include ramping, linearized increasing and decreasing modes.
Autotune
The AUTOTUNE function allows the FMA6500 to automatically optimize control response for the gas under actual process conditions. During the AUTOTUNE process, the instrument adjusts PID gains for optimum step response and determine key control valve characteristics (only available on units with less than 80 L/min maximum flow).
Contact Closure
Two sets of dry contact relay outputs are provided to actuate user supplied equipment. These are programmable via the digital interface such that the relays can be made to switch when a specified event occurs (e.g. when a low or high flow alarm limit is exceeded or when the totalizer reaches a specified value).
Valve Override
Means are provided to force the control valve fully open (purge) or fully closed via either the analog or digital interfaces.
Self Diagnostics
Whenever power is first applied, the FMA6500 runs a series of SELF DIAGNOSTIC TESTS to ensure that it is in optimum working condition.
Engineering Units
The flow setpoint, measured gas flow and associated totalizer data is scaled directly in engineering units via digital interface commands. The following units of measure are supported: % of FS, mL/min, mL/hr, scfm, scfh, sL/min, sL/hr, lbs/hr, lbs/min, and one user defined unit of measure.
Leak Integrity
1 x 10-9 smL/sec of Helium maximumto the outside environment.
Balanced Power Supply
The FMA6500 operates on ±15 Vdc. The current requirements for the positive and negative power supplies are balanced such that the current in the power supply common connection is minimized. Maximum power consumption is 13.5 watts at ±15 Vdc.
Product Number | Category | Media type | Flow Range | Accuracy | Communications Protocol | Output Signal | Wetted Materials | Display | Max Operating Pressure | Max Process Temperature | Process Connection Type: | Process Connection Size: | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
FMA6502ST $2,185.80
|
Controller
|
Gas
|
0.2 to 10 SCCM
|
±1%
|
RS485
|
0 to 5 Vdc
|
316 SS, 416 SS, FKM
|
No Display
|
500 psi
|
50 °C (122 °F)
|
Compression fitting
|
1/4″
|
2 SPDT 1A Relay
|
FMA6504ST $2,185.80
|
Controller
|
Gas
|
0.4 to 20 SCCM
|
±1%
|
RS485
|
0 to 5 Vdc
|
316 SS, 416 SS, FKM
|
No Display
|
500 psi
|
50 °C (122 °F)
|
Compression fitting
|
1/4″
|
2 SPDT 1A Relay
|
FMA6506ST $2,185.80
|
Controller
|
Gas
|
1 to 50 SCCM
|
±1%
|
RS485
|
0 to 5 Vdc
|
316 SS, 416 SS, FKM
|
No Display
|
500 psi
|
50 °C (122 °F)
|
Compression fitting
|
1/4″
|
2 SPDT 1A Relay
|
FMA6508ST $2,185.80
|
Controller
|
Gas
|
2 to 100 SCCM
|
±1%
|
RS485
|
0 to 5 Vdc
|
316 SS, 416 SS, FKM
|
No Display
|
500 psi
|
50 °C (122 °F)
|
Compression fitting
|
1/4″
|
2 SPDT 1A Relay
|
FMA6510ST $2,185.80
|
Controller
|
Gas
|
4 to 200 SCCM
|
±1%
|
RS485
|
0 to 5 Vdc
|
316 SS, 416 SS, FKM
|
No Display
|
500 psi
|
50 °C (122 °F)
|
Compression fitting
|
1/4″
|
2 SPDT 1A Relay
|
FMA6512ST $2,185.80
|
Controller
|
Gas
|
10 to 500 SCCM
|
±1%
|
RS485
|
0 to 5 Vdc
|
316 SS, 416 SS, FKM
|
No Display
|
500 psi
|
50 °C (122 °F)
|
Compression fitting
|
1/4″
|
2 SPDT 1A Relay
|
FMA6514ST $2,185.80
|
Controller
|
Gas
|
0.02 to 1 SLM
|
±1%
|
RS485
|
0 to 5 Vdc
|
316 SS, 416 SS, FKM
|
No Display
|
500 psi
|
50 °C (122 °F)
|
Compression fitting
|
1/4″
|
2 SPDT 1A Relay
|
FMA6516ST $2,185.80
|
Controller
|
Gas
|
0.04 to 2 SLM
|
±1%
|
RS485
|
0 to 5 Vdc
|
316 SS, 416 SS, FKM
|
No Display
|
500 psi
|
50 °C (122 °F)
|
Compression fitting
|
1/4″
|
2 SPDT 1A Relay
|
FMA6518ST $2,185.80
|
Controller
|
Gas
|
0.1 to 5 SLM
|
±1%
|
RS485
|
0 to 5 Vdc
|
316 SS, 416 SS, FKM
|
No Display
|
500 psi
|
50 °C (122 °F)
|
Compression fitting
|
1/4″
|
2 SPDT 1A Relay
|
FMA6520ST $2,185.80
|
Controller
|
Gas
|
0.2 to 10 SLM
|
±1%
|
RS485
|
0 to 5 Vdc
|
316 SS, 416 SS, FKM
|
No Display
|
500 psi
|
50 °C (122 °F)
|
Compression fitting
|
1/4″
|
2 SPDT 1A Relay
|
FMA6523ST $2,331.44
|
Controller
|
Gas
|
0.3 to 15 SLM
|
±1%
|
RS485
|
0 to 5 Vdc
|
316 SS, 416 SS, FKM
|
No Display
|
500 psi
|
50 °C (122 °F)
|
Compression fitting
|
1/4″
|
2 SPDT 1A Relay
|
FMA6524ST $2,331.44
|
Controller
|
Gas
|
0.4 to 20 SLM
|
±1%
|
RS485
|
0 to 5 Vdc
|
316 SS, 416 SS, FKM
|
No Display
|
500 psi
|
50 °C (122 °F)
|
Compression fitting
|
1/4″
|
2 SPDT 1A Relay
|
FMA6526ST $2,331.44
|
Controller
|
Gas
|
0.6 to 30 SLM
|
±1%
|
RS485
|
0 to 5 Vdc
|
316 SS, 416 SS, FKM
|
No Display
|
500 psi
|
50 °C (122 °F)
|
Compression fitting
|
1/4″
|
2 SPDT 1A Relay
|
FMA6527ST $2,331.44
|
40 SCCM
|
15 to 25°C (59 to 77°F) and 0.7 to 4 bar (10 to 60 psia) ±1% of FS, 0 to 50°C (32 to 122°F) and 0.3 to 10 bar (5 to 150 psia) ±2% of FS, ±1% of FS
|
316 Stainless Steel
|
RS485
|
Air
|
||||||||
FMA6528ST $2,331.44
|
Controller
|
Gas
|
1 to 50 SLM
|
±1%
|
RS485
|
0 to 5 Vdc
|
316 SS, 416 SS, FKM
|
No Display
|
500 psi
|
50 °C (122 °F)
|
Compression fitting
|
1/4″
|
2 SPDT 1A Relay
|
FMA6540ST $2,481.54
|
Controller
|
Gas
|
1.2 to 60 SLM
|
±1%
|
RS485
|
0 to 5 Vdc
|
316 SS, 416 SS, FKM
|
No Display
|
500 psi
|
50 °C (122 °F)
|
Compression fitting
|
3/8″
|
2 SPDT 1A Relay
|
FMA6541ST $2,481.54
|
Controller
|
Gas
|
1.6 to 80 SLM
|
±1%
|
RS485
|
0 to 5 Vdc
|
316 SS, 416 SS, FKM
|
No Display
|
500 psi
|
50 °C (122 °F)
|
Compression fitting
|
3/8″
|
2 SPDT 1A Relay
|
FMA6542ST $2,481.54
|
Controller
|
Gas
|
2 to 100 SLM
|
±1%
|
RS485
|
0 to 5 Vdc
|
316 SS, 416 SS, FKM
|
No Display
|
500 psi
|
50 °C (122 °F)
|
Compression fitting
|
3/8″
|
2 SPDT 1A Relay
|
You can request the necessary certificates, documentation, instructions and user guide for OMEGA FMA6500 using the special form.
You can buy OMEGA FMA6500 in UAE at a price starting from 2,185.80 $ in «Texair FZCO» by leaving a request on the website, by phone +441225535040 or by email ceo@texair.eu. OMEGA FMA6500 price are subject to change depending on exchange rates. We deliver instruments by transport companies in United Arab Emirates, Kuwait, Qatar, Saudi Arabia, Saudi Arabia, Bahrain and other Middle Eastern countries.
See also: Flow meters