+971 56 389 7151

Mon-Fri: 8:00 - 18:00 UAE

Email:

MACURCO CD-6MC/CD-12MC Carbon Dioxide Fixed Gas Detector

CD-6MC: Low Voltage (12 to 24 VAC or 12 to 32 VDC)/CD-12MC: Line Voltage (100-240 VAC)

The CD-6/12MC monitor detects Carbon Dioxide (CO2) in the beverage and food industries, refrigeration, welding, greenhouses, pharmaceutical, and other chemical processing or other commercial applications, as well as providing automatic fan control to help maintain acceptable levels of gas. Can be used as a stand-alone detector and controller and as an analog transducer for use with the DVP-120 and other systems.

			int(25882)
NULL
		

Made in USA. brand MACURCO, model CD-6MC/CD-12MC

International delivery to United Arab Emirates, Kuwait, Qatar, Saudi Arabia, Saudi Arabia, Bahrain, Oman and other Middle Eastern countries.
Our warehouses are located in UAE. Delivery to other countries (Europe, North and South America, Asia, Africa) is discussed individually.

price По запросу

Available

Available

Advantages

Only the best I&C brands

Our company is a UAE supplier of control and measuring instruments from well-known world brands

Advantages

Discounts for organisations

We sell high-tech equipment at best prices. We provide really advantageous conditions for partners

Advantages

Fast delivery across the Middle East

Supply to United Arab Emirates, Kuwait, Qatar, Saudi Arabia, Bahrain, Oman and other countries

Advantages

Professional advice on device selection

Our specialists are ready to advise you on any technical question. We can find an analogue of any device

Description of MACURCO CD-6MC/CD-12MC

Key features

  • ETL LISTED to UL 61010-1, Certified to CSA C22.2#61010-1
  • Low level meter capable of displaying from 0-5000 ppm of COP 2
  • Sensor Resolution of 50 ppm
  • The CD-xxH uses an automated background calibration program to set the clean air level on a regular basis *
  • The CD-xxMC uses a manual Calibration to set clean and polluted air levels using a Calibration Kit **
  • Selectable fan and alarm relay activation
  • 5 A SPDT fan relay for control of ventilation systems / communication with Alarm system
  • 0.5 A N.O. or N.C. alarm relay connects to warning devices or control panels
  • 4-20 mA Current Loop
  • Mounts on a standard 4×4 electrical box and becomes cover for the box
  • Supervised system: any internal detector problem will cause the fan & alarm relay to activate
  • Carbon Dioxide sensor has an expected 15-year life. EOL indicator after 180 months of sensor power-up
  • Calibration verification test kit is available. One screw allows access for gas tes

*CD-xxH Only
**CD-xxMC Only

Applications

  • Parking garages
  • Mechanical rooms
  • Restaurants
  • Battery charging stations
  • Breweries
  • Storage facilities
  • Loading docks
  • Warehouses
  • Firehouses & ambulance bays
  • Refrigeration facilities
  • Vehicle repair facilities
  • Bus depots

Technical specifications of MACURCO CD-6MC/CD-12MC

Shipping Weight 1 pound (0 45 kg)
Size 4 1/2 x 4 x 2 1/8 in (11 4 X 11 4 X 5 3 cm)
Color White or Dark Gray
Connections plugs/terminals
Mounting box (not included) 4×4 electric
Fan relay 5 A, 240 VAC, pilot duty, SPDT, latching or non-latching
Fan relay actuation selectable at dIS (disabled), 600, 700, 800, 900, 1000 (default)…, 4800, 4900, 5000 ppm
Fan Delay Settings 0, 1, 3 (default), 5 and 10 minutes
Fan Relay Minimum Runtime settings 0 (default), 3, 5, 10 or 15 minutes
Fan relay latching or non-latching (default) selectable
Alarm relay 0 5A 120 V, 60 VA
Alarm relay actuation selectable N O (default) or N C
Alarm relay settings “dIS” (disabled), 900, 1000, 1100, 1200, …4000(default), … 4900, 5000
Current Loop 4-20 mA for 0-5000 ppm COP 2P, selectable to off or on (default)
Buzzer 85 dBA at 10cm settable to off or on (default)
Digital display 4-digit LED selectable to off or on (default)
Operating Environment 32°F to 122° F (0°C to 50°C), 10 to 90% RH non-condensing
Operating altitude Up to 16,404ft (5,000m)
Expand Table

How to buy MACURCO CD-6MC/CD-12MC

Model Number Gas Type Range (Units) Low Level Alarm Adjustable (Default) High Level Alarm Adjustable (Default) Expected Sensor Life Recommended Coverage Area
CD-6MC | CD-12MC Carbon Dioxide (CO₂) 0-5,000 PPM 0,500,100,100,100,100… 0,900,100,100…4000…10-5000 PPM 15 Years Up to 5000 sq. ft.*
Expand Table

Accessories for

Photo Model Description
DVP-120, DVP-120M, DVP-120B, DVP-1200 Control Panels
PS-24, PS-24-H Step-down Transformers
DMK-1 Duct Mount Kit
HS-A, HS-B, HS-R, HS-C Horn and Strobe (4 color options)
MRS-485, BRS-485 Adapter Options
Calibration Kits Based on Gas Type
WHK-1 Weatherproof Housing Kit

User Guide and Instruction manual for MACURCO CD-6MC/CD-12MC

You can request the necessary certificates, documentation, instructions and user guide for MACURCO CD-6MC/CD-12MC using the special form.

You can buy MACURCO CD-6MC/CD-12MC in UAE at a price starting from По запросу $ in «Texair FZCO» by leaving a request on the website, by phone +441225535040 or by email . MACURCO CD-6MC/CD-12MC price are subject to change depending on exchange rates. We deliver instruments by transport companies in United Arab Emirates, Kuwait, Qatar, Saudi Arabia, Saudi Arabia, Bahrain and other Middle Eastern countries.

Generate an article by selecting the parameters below
Article:
Quantity:
-
+
Clear
I know the article / Need help
Select accessories
The article is not fully generated. Please double-check the selected values.
Generate an article by selecting the parameters below
Accessories:
-
Clear
Get Offer