GEORGIN FKP Relative pressure transmitter

  • SMART Transmitter 4-20mA + HART protocol
  • Span limits : -1 to 100 bar
  • Rangeability : 16:1
  • Accuracy : 0.1%
  • Power supply 10.5 to 45 VDC
  • Process wetted parts material 316L stainless steel
  • Process connection direct
  • Burnout signal according NAMUR NE43 recommandations
  • Long term stability : +/-0.1% of maximum span / 10years

Options: Local analog or digital Indicator; Intrinsically safe version; Explosion proof version; FM, CSA and IECEx certification; Stainless Steel electronic housing

			int(7638)
NULL
		

Made in France. brand GEORGIN, model FKP

International delivery to United Arab Emirates, Kuwait, Qatar, Saudi Arabia, Saudi Arabia, Bahrain, Oman and other Middle Eastern countries.
Our warehouses are located in UAE. Delivery to other countries (Europe, North and South America, Asia, Africa) is discussed individually.

price by request

Available

Available

Advantages

Only the best I&C brands

Our company is a UAE supplier of control and measuring instruments from well-known world brands

Advantages

Discounts for organisations

We sell high-tech equipment at best prices. We provide really advantageous conditions for partners

Advantages

Fast delivery across the Middle East

Supply to United Arab Emirates, Kuwait, Qatar, Saudi Arabia, Bahrain, Oman and other countries

Advantages

Professional advice on device selection

Our specialists are ready to advise you on any technical question. We can find an analogue of any device

Description of GEORGIN FKP

The ProcessX pressure transmitter accurately measures gauge pressure and transmits proportional 4 to 20 mA signal. The transmitter utilizes the unique micromachined capacitive silicon sensor with state-of-the-art microprocessor technology to provide exceptional performance and functionality.

FEATURES

  • High accuracy ±0.1% 0.1% accuracy is a standard feature. Georgin’s microcapacitance silicon sensor assures this accuracy for all
    elevated or suppressed calibration ranges without additional adjustment.
  • Minimum inventory and design Electronics unit, local indicators and electronics housing are interchangeable among all ProcessX transmitters.
  • Minimum environmental influence The “Advance Floating Cell” design which protects the pressure sensor against changes in temperature, and overpressure substantially reduces total measurement error in actual field applications.
  • Georgin/HART® bilingual communications protocol ProcessX series transmitter offers bilingual communications to speak both Georgin proprietary protocol and HART®. Any HART® compatible devices can communicate with ProcessX.
  • Application flexibility: Various options that render the ProcessX suitable for almost any process applications include :
    •  Analog indicator at either the electronics side or terminal side,
    •  Full range of hazardous area approvals,
    • Built-in RFI filter and lightning arrester,
    • 5 digit LCD meter with engineering unit,
    • Stainless steel electronics housing,
    • Wide selection of materials.
  • Programmable output Linearization Function Output signal can be freely programmable (Up to 14 compensated points at approximation).
  • Burnout current flexibility (Under Scale: 3.2 to 4.0 mA, Over Scale: 20.0 to 22.5 mA) Burnout signal level is adjustable using Model FXW or Hand Held Communicator (HHC) to comply with NAMUR NE43.
  • Dry calibration without reference pressure Thanks to the best combination of unique construction of mechanical parts (Sensor unit) and high performance electronics circuit (Electronics unit), reliability of dry calibration without reference pressure is at equal level as wet calibration

Technical specifications of GEORGIN FKP

  • Type : FKH : Smart, 4-20 mA DC + Georgin/Hart® digital signal
  • Service : Liquid, gas, or vapour.
  • Lower range limit (vacuum limit) is :
    Silicone fill sensor : See Fig. 1
    Fluorinated fill sensor: 66 kPa abs (500 mmHg abs) at below 60°C.
  • Output signal : 4 to 20 mA DC with digital signal superimposed on the analogic signal.
  • Power supply : Transmitter operates on 10.5 to 45 V DC at transmitter terminals. 10.5 to 32 V DC for the units with optional arrester.

Span, range and overrange limit :

Type Span limit kPa {bar} Range limit kPa {bar} Overrange limit MPa {bar}
Min. Max.
FKP 01  8.125 {0.08125} 130 {1.3}  -100 à + 130 B10{-1 to +1.3} 1 {10}
FKP 02  31.25 {0.3125} 500 {5}  -100 à + 500 {-1 to +5} 1,5 {15}
FKP 03  187.5 {1.875} 3000 {30}  -100 à + 3000 {-1 to +30} 9 {90}
FKP 04 625 {6.25} 10000 {100}  -100 à + 10000 {-1 to +100} 15 {150}
Expand Table

User Guide and Instruction manual for GEORGIN FKP

You can request the necessary certificates, documentation, instructions and user guide for GEORGIN FKP using the special form.

You can buy GEORGIN FKP in UAE at a favourable price in «Texair FZCO» by leaving a request on the website, by phone +441225535040 or by email . GEORGIN FKP price are subject to change depending on exchange rates. We deliver instruments by transport companies in United Arab Emirates, Kuwait, Qatar, Saudi Arabia, Saudi Arabia, Bahrain and other Middle Eastern countries.