Michell XTP501 Thermo Paramagnetic Oxygen Analyzer

Non-Depleting Rugged Paramagnetic Sensor

  • Compact, lightweight and easy to install
  • Intuitive user interface
  • Tough IP55 housing
  • Low cost of ownership due to minimal maintenance
  • Measurement ranges from 0 to 1% up to 0…25 % O2 and 20/80/90…100 % O2
  • Accuracy of better than ±1 % full scale
  • 2 x 4…20 mA outputs and Modbus RTU over RS485 as standard
			int(21139)
NULL
		

Made in United Kingdom. brand Michell, model XTP501

International delivery to United Arab Emirates, Kuwait, Qatar, Saudi Arabia, Saudi Arabia, Bahrain, Oman and other Middle Eastern countries.
Our warehouses are located in UAE. Delivery to other countries (Europe, North and South America, Asia, Africa) is discussed individually.

price По запросу

Available

Available

Advantages

Only the best I&C brands

Our company is a UAE supplier of control and measuring instruments from well-known world brands

Advantages

Discounts for organisations

We sell high-tech equipment at best prices. We provide really advantageous conditions for partners

Advantages

Fast delivery across the Middle East

Supply to United Arab Emirates, Kuwait, Qatar, Saudi Arabia, Bahrain, Oman and other countries

Advantages

Professional advice on device selection

Our specialists are ready to advise you on any technical question. We can find an analogue of any device

Description of Michell XTP501

A lightweight oxygen analyzer or transmitter for cost-effective quality control in safe area applications, such as monitoring oxygen purity. Using Michell’s tried and tested Thermo-Paramagnetic oxygen sensing technology the XTP501 has no consumable parts to replace and offers users an extremely low cost of ownership due to minimal maintenance needs.

Technical specifications of Michell XTP501

Technical Specifications
Product XTP601 XTP501
Performance Specifications
Measurement Technology Thermo-paramagnetic oxygen sensor
Measured Gas Oxygen (O2)
Background Gas Analyzer is calibrated in the background gas of the process. Standard backgrounds include N2, CO2, CH4, H2, He & BIOGAS.
Gas Requirements Non-condensing sample with particles <3μm
Measurement Range Analyzer is calibrated to the range the customer requires. Select from: 0…0.5% up to 0…50% and 20…100% up to 90…100%
Display Resolution 0.01%; 0.1% for suppressed zero ranges N/A
Display Type Backlit LCD (not on 501-GP2 model) N/A
Intrinsic Error (Accuracy) < ±1% of range or ±0.02% O2, whichever is greater
< ±0.2% O2 or ±1% of range, whichever is greater (for suppressed zero ranges 20/80/90 to 100%)
N/A
Response Time (T90) < 15 seconds (with High Speed Response (HSR) Enabled) N/A
Repeatability ±0.2% of range or ±0.02% O2, whichever is greater N/A
Linearity ±0.5% of range or ±0.05% O2, whichever is greater N/A
Zero Stability ±0.25% of range per month N/A
Range Stability ±0.25% of range per month N/A
Sample Flow Rate (General Purpose) 100…500 ml/min (0.25…1.0 scfh) N/A
Sample Flow Rate (Ex Version) 270…330 ml/min (0.57…0.7 scfh) N/A
Sample Flow Effect < 1% of range for flows within stated range (calibrated at 300 ml/min) N/A
Sample Pressure 0.75…2 BarA (unit must be calibrated at the same pressure as sample) N/A
Sample Temperature A constant temperature of +5…+45/+55 °C (+41…+113/+131 °F) A constant temperature of +5…+45 °C (+41…+113 °F)
Sample Cell Temperature +50/+60 °C (+122/+140 °F) +50 °C (+122 °F)
Electrical Specifications
Analog Inputs 1 off mA input for an external sensor (can be displayed on the screen)
1 off mA input to act as an active compensation for the process conditions
Analog Outputs 2 off 4…20 mA outputs (powered with 24V excitation voltage)
Output Ranges Primary range is set to the calibrated range of the instrument. The second is user-selectable
Alarms 2 off single pole changeover relays for O2 concentration (250 V, 5 A max)
Datalogging Digital communications can be used to log the output from the analyzer on an external device
Digital Communications Modbus RTU over RS485
Power Supply 24 V DC, 1.6 A max
Operating Conditions
Ambient Temperature +5…+60 °C (+41 °F…+140 °F) +5…+50 °C (+41 °F…+122 °F) cQPSus
Mechanical Specifications
Warm-up Time < 25 minutes (at 20 °C/68 °F ambient) N/A
Stabilization Time 5 minutes N/A
Wetted Materials 316L stainless steel, borosilicate glass, platinum, (plus O-ring) N/A
Dimensions (w x d x h) 234 x 234 x 172 mm (9.21 x 9.21 x 6.77”) 260 x 180 x 128 mm (10.24 x 7.09 x 5.04”)
Weight 9.7 kg (21.3 lbs) Approx. 3 kg (6.6 lbs)
O-Ring Materials Viton, Silicone or EKraz Viton
Gas Connection 1/4″ NPT Female (GP1)
1/8” NPT Female (Ex & GP2)
1/8″ bulkhead standard
Ingress Protection IP66, NEMA 4X IP55
Hazardous Area Classification
ATEX/UKCA II 2 G D Ex db IIB +H2 T6 Gb Ex tb IIIC T85 °C Db IP66 N/A
IECEx Ex db IIB +H2 T6 Gb Ex tb IIIC T85 °C Db IP66 N/A
Temperature Ranges for ATEX/UKCA and IECEx as per O-Ring Type Silicon: Ta O-ring = -40 °C…+60 °C
Viton: Ta O-ring = -15 °C…+60 °C
Ekraz: Ta O-ring = -10 °C…+60 °C
N/A
cQPSus Class I, Division 1, Groups BCD T6
Class II, Division 1, Groups EFG
Class I, Zone 1, AEx/Ex db IIB+H2 T6 Gb
Zone 21 AEx/Ex tb IIIC T85°C Db
N/A
TR CU Ex 1Ex d IIB+H2 T6 Gb N/A
Expand Table

* Maximum temperature of +50 °C for North America, +55 °C for TR CU Ex (EAC).

User Guide and Instruction manual for Michell XTP501

You can request the necessary certificates, documentation, instructions and user guide for Michell XTP501 using the special form.

You can buy Michell XTP501 in UAE at a price starting from По запросу $ in «Texair FZCO» by leaving a request on the website, by phone +441225535040 or by email . Michell XTP501 price are subject to change depending on exchange rates. We deliver instruments by transport companies in United Arab Emirates, Kuwait, Qatar, Saudi Arabia, Saudi Arabia, Bahrain and other Middle Eastern countries.

See also: Other instruments

Generate an article by selecting the parameters below
Article:
Quantity:
-
+
Clear
I know the article / Need help
Get Offer
The article is not fully generated. Please double-check the selected values.