+971 56 389 7151

Mon-Fri: 8:00 - 18:00 UAE

Email:

Rotronic HC2A-S3, S3H Meteo Humidity Probe

High-Temperature probe for harsh environment and Temperatures up to -100…200 °C

  • Range of application -100…200 °C / 0…100 %RH
  • Accuracy: ±0.8 %RH, ±0.1 K, at 23 °C ±5 K
  • Digital interface (UART) and scalable analog outputs, 0…1 V
  • GAMP compatible (HygroSoft Software)
			int(21266)
NULL
		

Made in Swiss. brand Rotronic, model HC2A-S3, S3H

International delivery to United Arab Emirates, Kuwait, Qatar, Saudi Arabia, Saudi Arabia, Bahrain, Oman and other Middle Eastern countries.
Our warehouses are located in UAE. Delivery to other countries (Europe, North and South America, Asia, Africa) is discussed individually.

price По запросу

Available

Available

Advantages

Only the best I&C brands

Our company is a UAE supplier of control and measuring instruments from well-known world brands

Advantages

Discounts for organisations

We sell high-tech equipment at best prices. We provide really advantageous conditions for partners

Advantages

Fast delivery across the Middle East

Supply to United Arab Emirates, Kuwait, Qatar, Saudi Arabia, Bahrain, Oman and other countries

Advantages

Professional advice on device selection

Our specialists are ready to advise you on any technical question. We can find an analogue of any device

Description of Rotronic HC2A-S3, S3H

The standard Rotronic Humidity and Temperature probes can be used in application with temperatures from -50…100 °C / 0…100 %RH. With an outstanding accuracy of ± 0.8 %RH / ± 0.1°C. For calibration purposes the probes can be replaced without almost any downtime. Together with a Rotronic MP102H / MP402H Meteotransmitter or together with weather shield the HC2A-S3(H) probe is the first selection for many applications.

The HC2A-S3(H) are the second most sold versatile probe from Rotronic and form the basis of the meteorological and outdoor application product portfolio. They measure Humidity and Temperature and can calculate the dew-/ frost point.

Applications

  • Meteorology & Wheater Forecast
  • Outdoor Environments
  • Reference Probe for Snow Guns, Meteo & Research Stations

Technical specifications of Rotronic HC2A-S3, S3H

Supply voltage 3,3…5 VDC
Current consumption Approx. 5 mA (Adjusted at 3.3 VDC)
Load > 10 kW
Protection rating IP65 (except the sensor area)
Digital Interface UART (19200 baud fixed)
Protocols •  RoASCII (Default)

•  MODBUS (setting with HW4)

Analog outputs 2x 0…1 V
Analog outputs Parameters •  Humidity (default)

•  Temperature (default)

•  Dew point (setting with HW4)

•  Frost point (setting with HW4)

Analog output scaling •  Humidity (0…100 %rh = 0…1V)

•  Temperature (-40…60 = 0…1V)

•  Freely settable with HW4

Timing 1st measurement after 1.5 s Measurement interval of 1 s
Expand Table

Model Chart of Rotronic HC2A-S3, S3H

High Precision probes are factory-adjusted at 23°C and 10, 20, 30, 40, 50, 60, 70, 80, 90 %rh, then calibrated at 20, 50, 80 %rh.

Order Code Type Accuracy @ 23 °C Application Range Sensor Element Long-term stability
HC2A-SH High Precision ±0.5 %rh

±0.1 K

-50..100 °C

0…100 %rh

HYGROMER HT-1 <1 %rh per year with clean air
HC2A-S3H Meteo 4 High Precision
Expand Table

Standards Precision probes are factory-adjusted at 23°C and 10, 35, 80 %RH.

Order Code Type Accuracy @ 23 °C Application Range Sensor Element Long-term stability
HC2A-S Standard ±0.8 %rh

±0.1 K

 

 

-50..100 °C

0…100 %rh

 

HYGROMER HT-1

 

 

<1 %rh per year with clean air

HC2A-S3 Meteo4 Standard
HC2A-SM Steel Probe
HC2A-S-HH Standard Probe for Rough environment 5 ±1.0 %rh

±0.1 K

Hygromer HH-1
Expand Table

The cable AC3001 allows direct connection to a computer via USB and, with use of the HW5 software to adjust the HC2A probe’s parameters such as

  • Scale of Analog outputs
  • Calculated parameter on analog outputs

Possible Filters

Order Code Filter carrier Filter Element Pore size Application Range
SPA-PCB-PE  

Polycarbonate, black

Polyethylene, white 40-50 μm  

 

 

-50…100 °C

SPA-PCB-PTFE PTFE, white 10 μm
SPA-PCB-WM Wire mesh 1.4401
SPA-PCW-PE  

Polycarbonate, white

Polyethylene, white 40-50 μm
SPA-PCW-PTFE PTFE, white 10 μm
SPA-PCW-WM Wire mesh 1.4401
SPA-PE  

No filter carrier, only filter

Polyethylene 40-50 μm
SPA-PTFE PTFE, white  

10 μm

 

 

 

-100…200 °C

SPA-WM Wire mesh 1.4401
SPA-SS-WM 1,4301
SPA-SSS Sintered steel, 1.4404 (Carrier and filter) 25 μm
SPA-SS-PFTE Stainless steel, 1.4301 Teflon 10 μm
SPA-SS No filter
Expand Table

Standard: HC2A-S + SPA-PCB-PE with filter (Polyethylene, white)

4 The housing is full white to avoid any heating from sun radiation.

5  Especially suitable for environments with hydrogen peroxide (H2O2). Please refer the HYGROMER HH-1 datasheet for more information.

User Guide and Instruction manual for Rotronic HC2A-S3, S3H

You can request the necessary certificates, documentation, instructions and user guide for Rotronic HC2A-S3, S3H using the special form.

You can buy Rotronic HC2A-S3, S3H in UAE at a price starting from По запросу $ in «Texair FZCO» by leaving a request on the website, by phone +441225535040 or by email . Rotronic HC2A-S3, S3H price are subject to change depending on exchange rates. We deliver instruments by transport companies in United Arab Emirates, Kuwait, Qatar, Saudi Arabia, Saudi Arabia, Bahrain and other Middle Eastern countries.

Generate an article by selecting the parameters below
Article:
Quantity:
-
+
Clear
I know the article / Need help
Get Offer
The article is not fully generated. Please double-check the selected values.