On-site and In-Lab Humidity and Temperature Probe Calibration
Made in Swiss. brand Rotronic, model HygroCal100
International delivery to United Arab Emirates, Kuwait, Qatar, Saudi Arabia, Saudi Arabia, Bahrain, Oman and other Middle Eastern countries.
Our warehouses are located in UAE. Delivery to other countries (Europe, North and South America, Asia, Africa) is discussed individually.
price По запросу
Available
Only the best I&C brands
Our company is a UAE supplier of control and measuring instruments from well-known world brands
Discounts for organisations
We sell high-tech equipment at best prices. We provide really advantageous conditions for partners
Fast delivery across the Middle East
Supply to United Arab Emirates, Kuwait, Qatar, Saudi Arabia, Bahrain, Oman and other countries
Professional advice on device selection
Our specialists are ready to advise you on any technical question. We can find an analogue of any device
The HygroGen2 satisfies the stringent demands of quality and compliance regulations with its ability to calibrate instruments over their full working range, and is embraced throughout the pharmaceutical industry as the leading instrument in its class and is favored in ISO 17025 humidity calibration laboratories across the world. Being portable and robust, it can be set up at the installation location allowing for complete system qualification. The rock-solid stability, minimal thermal gradients and quick set-point changes of Hygro- Gen2-S are now replicated in a new family member: HygroGen2-XL, which boasts a much larger chamber.
Since its launch, the Rotronic HygroGen has defined the standard for portable humidity and temperature calibration. Hundreds of users worldwide have identified that this tool for the rapid generation of stable temperature and humidity conditions can save significant amounts of time in performing calibrations of all types of humidity instruments from all manufacturers.
HygroGen2 HG2-S
The HygroGen2 further satisfies the stringent demands of quality and compliance regulations with its ability to calibrate instruments over their full working range, and is embraced throughout the pharmaceutical industry as the leading instrument in its class and is favored in ISO 17025 humidity calibration laboratories across the world. Being portable and robust, it can be set up at the installation location allowing for complete system qualification.
HygroGen2 HG2-XL
The rock-solid stability, minimal thermal gradients and quick set-point changes of HygroGen2-S are replicated in the HygroGen2 HG2-XL, which boasts a chamber with 10 times the capacity.
Applications
| General Specifications | HG2-S | HG2-XL | |
| Chamber Volume | 2 liters | 20 liters | |
| Working Volume | 1.5 liters | 17 liters | |
| Humidity Changes (<±0.1 %rh stability) | 5…95 %rh | <5 minutes | <15 minutes |
| Temperature Changes (<±0.01 °C stability) | 23…50 °C | <5 minutes | <15 minutes |
| 23…0 °C | <25 minutes | <35 minutes | |
| Thermal Gradients | 15…50 °C | <±0.05 °C | <±0.05 °C |
| 5…60 °C | <±0.1 °C | <±0.1 °C | |
| 0…5 °C | <±0.15 °C | <±0.15 °C | |
| Probe Mounts | Up to 6 probes through door ports | Up to 19 probes through door, plus internal shelf racks | |
| Weight & Dimensions | 13 kg, 45 x 41 x 21 cm | 37 kg, 80 x 62 x 41 cm | |
| Generation Method | Mixed flow with desiccant drier cell and piezoelectric humidifier; Peltier thermoelectric element with radial chamber mixing fan | ||
| Control Probe Specification | ±1.3 %rh (0…10 °C and 30…50 °C) and ±1.8 %rh (50…60 °C) | ||
| Typical Calibration Uncertainty | ±1.5 %rh (k=2) at 23 °C, ±0.15 °C (k=2) 15…50 °C | ||
| Sensor | HygroClip2, capacitive RH sensor, Pt100 temperature sensor | ||
| Control Type | Embedded multiple PID controller, touch screen graphical user interface | ||
| Programmer Function | 20 user program memory, up to 200 set-point changes per program | ||
| External Sample Loop for Chilled Mirror Reference | Temperature controlled outlet and inlet, 6 mm fittings | ||
| USB Ports | 7 front, 2 rear | ||
| Integrated Software | Rotronic HW5 (FDA 21 CFR part 11 compliant) | ||
| Water Level | Low and high alarm, bar graph status indication | ||
| Water Quality | UV sterilization, auto time cycling | ||
| Desiccant Condition | Condition monitored during control operation | ||
| Optional Enhanced Features | Temperature / Humidity Range Extensions, AutoCal, External chilled mirror reference integration, Remote Screen Sharing, Remote API * | ||
| Power | 110…240 VAC 50/60 Hz, 3 A (240 VAC) 6A (110 VAC) | ||
| Enclosure | Powder coated aluminum and steel, IP20 | ||
| Operating Conditions | 10-35 °C, <2000 m altitude or less | ||
| CE UKCA | Safety | EN 61010-1:2001 | |
| EMC | EN 61326-1:2006 | ||
| EN 61000-6-1:2007 | |||
| Order codes | Description |
|---|---|
| HG2-S | HygroGen2 with touch screen, calibrated control/reference probe, set-point control & programmer function, heated sample loop, desiccant cell, fill syringe, embedded HW5-P. Order chamber door separately. |
| HG2-XL | HygroGen2-XL with touch screen, calibrated control/reference probe, set-point control & programmer function, heated sample loop, 2 x desiccant cell, fill syringe, embedded HW5-P. Chamber door included. |
| Chamber doors / probe sleeves / bungs | |
| HG2-D-888888 | HG2-S door 6 x 30 mm ports with 6 bungs, order specific B8 sleeves to suit smaller probe diameters |
| HG2-DP-00000 | HG2-S clear acrylic door (no ports) for instruments with displays |
| HG2-B8 | 30 mm bung for HG2-D-888888 |
| HG2-B8-xx | B8 probe sleeves for HG2-D-888888 (30 mm external, internal probe diameter see xx diameter codes) |
| HG2-D-xxxxx | HG2-S custom door for > 30 mm ports, ask your Rotronic dealer for the available doors |
| HG2-Bxxx | Custom bung |
| HG2-Bxx-xx | Custom probe adaptor sleeves |
| HG2-D-888888-Map | HG2-D888888 door with detachable mapping rig |
| Accessories | |
| HG2-TB | HG2-S transit bag, lightweight |
| HG2-TC | HG2-S heavy duty transit case |
| HG2-AC3001-L/050 | HygroClip2 calibration cable, 50 cm, USB |
| HG2-AC3001-L/050 (5) | HygroClip2 calibration cable, 50 cm, USB. Bundle of 5 pieces HG2-AC3001-L/050 |
| HG2-PRT-ring | PRT mounting ring for permanent monitoring of HG2-S using external temperature reference |
| Service & Consumables | |
| HG2-DES-3 | Molecular sieve desiccant (3 kg) |
| HG2-CAM | High resolution camera built into HG2-B8 bung |
You can request the necessary certificates, documentation, instructions and user guide for Rotronic HygroCal100 using the special form.
You can buy Rotronic HygroCal100 in UAE at a price starting from По запросу $ in «Texair FZCO» by leaving a request on the website, by phone +441225535040 or by email rop@texairmeasure.ae. Rotronic HygroCal100 price are subject to change depending on exchange rates. We deliver instruments by transport companies in United Arab Emirates, Kuwait, Qatar, Saudi Arabia, Saudi Arabia, Bahrain and other Middle Eastern countries.
See also: Humidity and Temperature Calibration