- standard (pipe) execution
- mineral insulated execution with sleeve
- Exi acc. to ATEX
Products not found
Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M2 Ex d I Mb (with connection head NS) II 2G Ex d IIC T6 Gb II 2D Ex t IIIC T85ºC Db IP66
- process connection with G1/2 or M20x1,5, 1/2NPT thread
- aluminium: XD-AD (AS1 – one cable gland, AS2 – two cable glands)
- aluminium, cover with window: XD-ADwin (AS3 – one cable gland, AS4 – two cable glands)
- stainless steel: XD-SD (NS1 – one cable gland, NS2 – two cable glands)
- sheath material: acid-resistant steel 1.4541
- cable gland: ATEX II 2 GD; ATEX I M2; IP 66÷68, cable diameter: 3÷14,3 mm (standard 6,1÷11,7)
- Exd acc. to ATEX
price По запросу
Temperature sensor suitable for measurement of outside temperature, both in places exposed to sun and not, mainly in air-conditioning and automation systems of district heating substations. Resistor is placed in a plastic housing. Optionally, sensor can be equipped with transmitter converting measured value to 4÷20mA current.
- closed-end sheath
- humidity max. 85% RH
- housing: material polycarbonate, IP67
- material: stainless steel 1.4541
price По запросу
Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M2 Ex d I Mb (with connection head NS) II 2G Ex d IIC T6 Gb II 2D Ext IIIC T85ºC Db IP66
- aluminium: XD-AD (AS1 – one cable gland, AS2 – two cable glands)
- aluminium, cover with window: XD-ADwin (AS3 – one cable gland, AS4 – two cable glands)
- stainless steel: XD-SD (NS1 – one cable gland, NS2 – two cable glands)
- sheath material: acid-resistant steel 1.4541, 1.4841, 1.4762
- cable gland: ATEX II 2 GD; ATEX I M2; IP 66÷68,cable diameter: 3÷14,3 mm (standard 6,1÷11,7)
- Exd acc. to ATEX
price По запросу
Sensor suitable for temperature measurement in district heating substations. Applicable for temperature measurement of liquid and gaseous media in high pressure conditions. This sensor consists of resistor placed in the thin-walled acid-resistant sheath with welded process connection and plug installed on the sheath. It is equipped with additional straight or angled connector for joining lead wire with outer devices
- connector operating temperature: (-40 ÷ 100) °C
- plug GDM + socket GSP (IP65)
- material: stainless steel 1.4541
- sheath constricted ø6/ø4 mm
price По запросу
Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M1 Ex ia (with connection head N1) II 1/2G Ex ia IIC T6 II 1/2D Ex ia IIIC T85°C cable gland II 2GD Ex eb IIc, Ex ta IIIC (for the cable 5÷10mm)
- process connection with G1/2 or M20x1,5 thread
- connection head type aluminium XE-DANA (S1-standard), XE-DAND (S2),
XE-DANAW (W1), XE-DANDW (W2) or stainless XE-BE (N1), IP65 - sheath material: acid-resistant steel 1.4541
- cable gland ATEX II GD IP65 (for cable 5÷10 mm)
- Exi acc. to ATEX
price По запросу
Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M2 Ex d I Mb (with connection head NS) II 2G Ex d IIC T6 Gb II 2D Ex t IIIC T85ºC Db IP66
- process connection with G1/2 or M20x1,5, 1/2NPT thread
- aluminium: XD-AD (AS1 – one cable gland, AS2 – two cable glands)
- aluminium, cover with window: XD-ADwin (AS3 – one cable gland, AS4 – two cable glands)
- stainless steel: XD-SD (NS1 – one cable gland, NS2 – two cable glands)
- sheath material: acid-resistant steel 1.4541, flange PN16, DN20. DN25
- cable gland: ATEX II 2 GD; ATEX I M2; IP 66÷68, cable diameter: 3÷14,3 mm (standard 6,1÷11,7)
- Exd acc. to ATEX
price По запросу
Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M1 Ex ia (with connection head N1) II 1/2G Ex ia IIC T6 II 1/2D Ex ia IIIC T85°C cable gland II 2GD Ex eb IIc, Ex ta IIIC (for the cable 5÷10mm)
- process connection with G1/2 or M20x1,5 thread
- connection head type aluminium XE-DANA (S1-standard), XE-DAND (S2),
XE-DANAW (W1), XE-DANDW (W2) or stainless XE-BE (N1), IP65 - sheath material: acid-resistant steel 1.4541
- cable gland ATEX II GD IP65 (for cable 5÷10 mm)
- Exi acc. to ATEX
price По запросу
Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M2 Ex d I Mb (with connection head NS) II 2G Ex d IIC T6 Gb II 2D Ex t IIIC T85ºC Db IP66
- aluminium: XD-AD (AS1 – one cable gland, AS2 – two cable glands)
- aluminium, cover with window: XD-ADwin (AS3 – one cable gland, AS4 – two cable glands)
- stainless steel: XD-SD (NS1 – one cable gland, NS2 – two cable glands)
- sheath material: acid-resistant steel 1.4541 or 1.7335
- cable gland: ATEX II 2 GD; ATEX I M2; IP 66÷68, cable diameter: 3÷14,3 mm (standard 6,1÷11,7)
- Exd acc. to ATEX
price По запросу
Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M1 Ex ia (with connection head N1) II 1/2G Ex ia IIC T6 II 1/2D Ex ia IIIC T85°C cable gland II 2GD Ex eb IIc, Ex ta IIIC (for the cable 5÷10mm)
- process connection with G1/2 or M20x1,5 thread
- connection head type aluminium XE-DANA (S1-standard), XE-DAND (S2),
XE-DANAW (W1), XE-DANDW (W2) or stainless XE-BE (N1), IP65 - sheath material: acid-resistant steel 1.4541
- cable gland ATEX II GD IP65 (for cable 5÷10 mm)
- Exi acc. to ATEX
price По запросу
Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M2 Ex d I Mb (with connection head NS) II 2G Ex d IIC T6 Gb II 2D Ex t IIIC T85ºC Db IP66
- aluminium: XD-AD (AS1 – one cable gland, AS2 – two cable glands)
- aluminium, cover with window: XD-ADwin (AS3 – one cable gland, AS4 – two cable glands)
- stainless steel: XD-SD (NS1 – one cable gland, NS2 – two cable glands)
- sheath material: acid-resistant steel 1.4541 flange PN16, DN20, DN25
- cable gland: ATEX II 2 GD; ATEX I M2; IP 66÷68, cable diameter: 3÷14,3 mm (standard 6,1÷11,7)
- Exd acc. to ATEX
price По запросу
Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M1 Ex ia (with connection head N1) II 2G Ex ia IIC T6 II 2D Ex ia IIIC T85°C cable gland II 2GD Ex eb IIc, Ex ta IIIC (for the cable 5÷10mm)
- process connection with G1/2 or M20x1,5 thread
- connection head type aluminium XE-DANA (S1-standard), XE-DAND (S2),
XE-DANAW (W1), XE-DANDW (W2) or stainless XE-BE (N1), IP65 - sheath material: acid-resistant steel 1.4541, 1.4841 or 1.4762
- cable gland ATEX II GD IP65 (for cable 5÷10 mm)
- Exi acc. to ATEX
price По запросу
Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M2 Ex d I Mb (with connection head NS) II 2G Ex d IIC T6 Gb II 2D Ex t IIIC T85ºC Db IP66
- process connection with G1/2 or M20x1,5, 1/2NPT thread
- aluminium: XD-AD (AS1 – one cable gland, AS2 – two cable glands)
- aluminium, cover with window: XD-ADwin (AS3 – one cable gland, AS4 – two cable glands)
- stainless steel: XD-SD (NS1 – one cable gland, NS2 – two cable glands)
- sheath material: acid-resistant steel 1.4541
- cable gland: ATEX II 2 GD; ATEX I M2; IP 66÷68, cable diameter: 3÷14,3 mm (standard 6,1÷11,7)
- Exd acc. to ATEX
Db IP66
price По запросу
Temperature sensor suitable for measurement of liquid and gaseous media. Temperature sensor has ATEX approval for application in hazardous area: I M1 Ex ia (with connection head N1) II 2G Ex ia IIC T6 II 2D Ex ia IIIC T85°C cable gland II 2GD Ex eb IIc, Ex ta IIIC (for the cable 5÷10mm)
- process connection with G1/2 or M20x1,5 thread
- connection head type aluminium XE-DANA (S1-standard), XE-DAND (S2),
XE-DANAW (W1), XE-DANDW (W2) or stainless XE-BE (N1), IP65 - sheath material: acid-resistant steel 1.4541
- cable gland ATEX II GD IP65 (for cable 5÷10 mm)
- Exi acc. to ATEX
price По запросу
Temperature sensor suitable for measurement of liquid and gaseous media. Temperature sensor has ATEX approval for application in hazardous area: I M2 Ex d I Mb (with connection head NS) II 2G Ex d IIC T6 Gb II 2D Ex t IIIC T85ºC Db IP66
- aluminium: XD-AD (AS1 – one cable gland, AS2 – two cable glands)
- aluminium, cover with window: XD-ADwin (AS3 – one cable gland, AS4 – two cable glands)
- stainless steel: XD-SD (NS1 – one cable gland, NS2 – two cable glands)
- sheath material: acid-resistant steel 1.4541, 1.4571, 2.4816
- cable gland: ATEX II 2 GD; ATEX I M2; IP 66÷68, cable diameter: 3÷14,3 mm (standard 6,1÷11,7)
- Exd acc. to ATEX
price По запросу
Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M1 Ex ia (with connection head N1) II 1/2G Ex ia IIC T6 II 1/2D Ex ia IIIC T85°C cable gland II 2GD Ex eb IIc, Ex ta IIIC (for the cable 5÷10mm)
- process connection with G1/2 or M20x1,5 thread
- connection head type aluminium XE-DANA (S1-standard), XE-DAND (S2),
XE-DANAW (W1), XE-DANDW (W2) or stainless XE-BE (N1), IP65 - sheath material: boilert steel 1.4541
- cable gland ATEX II GD IP65 (for cable 5÷10 mm)
- Exi acc. to ATEX
price По запросу
Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M1 Ex ia (with connection head N1) II 1/2G Ex ia IIC T6 II 1/2D Ex ia IIIC T85°C cable gland II 2GD Ex eb IIc, Ex ta IIIC (for the cable 5÷10mm)
- process connection with G1/2 or M20x1,5 thread
- connection head type aluminium XE-DANA (S1-standard), XE-DAND (S2),
XE-DANAW (W1), XE-DANDW (W2) or stainless XE-BE (N1), IP65 - sheath material: stainless steel 1.4541
- cable gland ATEX II GD IP65 (for cable 5÷10 mm)
- Exi acc. to ATEX
price По запросу
Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M1 Ex ia (with connection head N1) II 1/2G Ex ia IIC T6 II 1/2D Ex ia IIIC T85°C cable gland II 2GD Ex eb IIc, Ex ta IIIC (for the cable 5÷10mm)
- process connection with G1/2 or M20x1,5 thread
- connection head type aluminium XE-DANA (S1-standard), XE-DAND (S2),
XE-DANAW (W1), XE-DANDW (W2) or stainless XE-BE (N1), IP65 - sheath material: acid-resistant steel 1.4541
- cable gland ATEX II GD IP65 (for cable 5÷10 mm)
- Exi acc. to ATEX
price По запросу
Temperature sensor with special sanitary flange connection Clamp type suitable for measurement in food and pharmaceutical industry. It has National Institute of Hygiene (PZH) attestation.
- process connection fl ange Clamp acc. to PN-ISO 2852
- connection head type MAA, BA; IP 54 -40÷100ºC
- MBEG, BEG – material: stainless steel 1.4541, IP65, -40÷100°C
- sheath material: acid-resistant steel 1.4541
- National Institute of Hygiene (PZH) attestation
price По запросу
Temperature sensor suitable for measurement of pipes and shafts. Rigid (pipe) sheath is joined to radiator enhancing the area of heat reception. Sensor has a band clamp that enables permanent radiator installation on pipe or shaft. Temperature sensor has ATEX approval for application in hazardous area: II 2G Ex ia IIC T6 II 2D Ex ia IIIC T85°C
- radiator enhancing surface of heat reception
- band clamp for mounting on a pipeline
- sheath material: brass
price По запросу
Temperature sensor suitable for measurement of surface to which it is attached. On the bottom of plastic housing aluminium radiator is placed, transferring heat from the adjacent surface. Thermometric resistor is placed in the radiator. Optionally, sensor can be equipped with transmitter converting measured value to 4÷20mA current.
- tangent surface temperature measurement
- measuring plate
- housing: material polycarbonate, IP67
- material: aluminium
price По запросу
Temperature sensor suitable for pipelines, pressure tanks and other devices used in food and pharmaceutical industry. This stainless steel sensor has National Institute of Hygiene (PZH) attestation.
- process connection with M10x1 or M20x1,5 thread
- connection head type MBEG – material: stainless steel 1.4541, IP65 -40÷100°C
- sheath material: acid-resistant steel 1.4541
- national Institute of Hygiene (PZH) attestation
price По запросу
Temperature sensor suitable for measurement in district heating substations. Applicable for temperature measurement of liquid and gaseous media in high pressure conditions. This sensor consists of sensing element placed in the thin-walled acid-resistant sheath with connector and flexible lead wire. Temperature sensor has ATEX approval for application in hazardous area: II 2G Ex ia IIC T6 II 2D Ex ia IIIC T85°C
price По запросу