+971 56 389 7151

Mon-Fri: 8:00 - 18:00 UAE

Email:

Advantages

Only the best I&C brands

Our company is a UAE supplier of control and measuring instruments from well-known world brands

Advantages

Discounts for organisations

We sell high-tech equipment at best prices. We provide really advantageous conditions for partners

Advantages

Fast delivery across the Middle East

Supply to United Arab Emirates, Kuwait, Qatar, Saudi Arabia, Bahrain, Oman and other countries

Advantages

Professional advice on device selection

Our specialists are ready to advise you on any technical question. We can find an analogue of any device

Device selection filter

Device selection filter

RTD Pt1000 Temperature Sensors in UAE

Download the questionnaire

TEXAIR FZCO – supplier of RTD Pt1000 Temperature Sensors in the UAE and MENA region with a sales office in Dubai, United Arab Emirates. Our company offers you to buy RTD Pt1000 Temperature Sensor at excellent price. International delivery available to Europe, Asia and Africa. Leave a request on the website and our specialists will send you a price list within 1-2 days.

Products not found

Temperature sensor suitable for measurement of living quarters and office space, mainly in ventilation and air-conditioning systems. Flexible housing made of plastic is adequate for wall mounting. Optionally, sensor can be equipped with transmitter converting measured value to 4÷20mA current.

  • without – unsheathed measuring resistor inside perforated housing
  • humidity max. 85% RH
  • material: ABS, IP-20
  • mounting holes span 48 mm

price По запросу

Read more
Available

Available

Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M2 Ex d I Mb (with connection head NS) II 2G Ex d IIC T6 Gb II 2D Ex t IIIC T85ºC Db IP66

  • process connection with G1/2 or M20x1,5 thread
  • aluminium: XD-AD (AS1 – one cable gland, AS2 – two cable glands)
  • aluminium, cover with window: XD-ADwin (AS3 – one cable gland, AS4 – two cable glands)
  • stainless steel: XD-SD (NS1 – one cable gland, NS2 – two cable glands)
  • sheath material: acid-resistant steel 1.4541
  • cable gland: ATEX II 2 GD; ATEX I M2; IP 66÷68, cable diameter: 3÷14,3 mm (standard 6,1÷11,7)
  • Exd acc. to ATEX

price По запросу

Read more
Available

Available

Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M2 Ex d I Mb (with connection head NS) II 2G Ex d IIC T6 Gb II 2D Ex t IIIC T85ºC Db IP66

  • process connection with G1/2 or M20x1,5, 1/2NPT thread
  • aluminium: XD-AD (AS1 – one cable gland, AS2 – two cable glands)
  • aluminium, cover with window: XD-ADwin (AS3 – one cable gland, AS4 – two cable glands)
  • stainless steel: XD-SD (NS1 – one cable gland, NS2 – two cable glands)
  • sheath material: acid-resistant steel 1.4541
  • cable gland: ATEX II 2 GD; ATEX I M2; IP 66÷68, cable diameter: 3÷14,3 mm (standard 6,1÷11,7)
  • Exd acc. to ATEX

price По запросу

Read more
Available

Available

Temperature sensor suitable for measurement of pipes and shafts. Rigid sheath is joined to radiator enhancing the area of heat reception. Sensor has a band clamp that enables permanent radiator installation on pipe or shaft.

  • radiator enhancing surface of heat reception with band clamp for mounting on a pipeline DN 15÷200 mm
  • insulated hot junction SO
  • material: brass

price По запросу

Read more
Available

Available

Temperature sensor suitable for measurement of outside temperature, both in places exposed to sun and not, mainly in air-conditioning and automation systems of district heating substations. Resistor is placed in a plastic housing. Optionally, sensor can be equipped with transmitter converting measured value to 4÷20mA current.

  • closed-end sheath
  • humidity max. 85% RH
  • housing: material polycarbonate, IP67
  • material: stainless steel 1.4541

price По запросу

Read more
Available

Available

Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M2 Ex d I Mb (with connection head NS) II 2G Ex d IIC T6 Gb II 2D Ext IIIC T85ºC Db IP66

  • aluminium: XD-AD (AS1 – one cable gland, AS2 – two cable glands)
  • aluminium, cover with window: XD-ADwin (AS3 – one cable gland, AS4 – two cable glands)
  • stainless steel: XD-SD (NS1 – one cable gland, NS2 – two cable glands)
  • sheath material: acid-resistant steel 1.4541, 1.4841, 1.4762
  • cable gland: ATEX II 2 GD; ATEX I M2; IP 66÷68,cable diameter: 3÷14,3 mm (standard 6,1÷11,7)
  • Exd acc. to ATEX

 

price По запросу

Read more
Available

Available

Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M1 Ex ia (with connection head N1) II 1/2G Ex ia IIC T6 II 1/2D Ex ia IIIC T85°C cable gland II 2GD Ex eb IIc, Ex ta IIIC (for the cable 5÷10mm)

  • process connection with G1/2 or M20x1,5 thread
  • connection head type aluminium XE-DANA (S1-standard), XE-DAND (S2),
    XE-DANAW (W1), XE-DANDW (W2) or stainless XE-BE (N1), IP65
  • sheath material: acid-resistant steel 1.4541
  • cable gland ATEX II GD IP65 (for cable 5÷10 mm)
  • Exi acc. to ATEX

price По запросу

Read more
Available

Available

Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M2 Ex d I Mb (with connection head NS) II 2G Ex d IIC T6 Gb II 2D Ex t IIIC T85ºC Db IP66

  • process connection with G1/2 or M20x1,5, 1/2NPT thread
  • aluminium: XD-AD (AS1 – one cable gland, AS2 – two cable glands)
  • aluminium, cover with window: XD-ADwin (AS3 – one cable gland, AS4 – two cable glands)
  • stainless steel: XD-SD (NS1 – one cable gland, NS2 – two cable glands)
  • sheath material: acid-resistant steel 1.4541, flange PN16, DN20. DN25
  • cable gland: ATEX II 2 GD; ATEX I M2; IP 66÷68, cable diameter: 3÷14,3 mm (standard 6,1÷11,7)
  • Exd acc. to ATEX

price По запросу

Read more
Available

Available

Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M1 Ex ia (with connection head N1) II 1/2G Ex ia IIC T6 II 1/2D Ex ia IIIC T85°C cable gland II 2GD Ex eb IIc, Ex ta IIIC (for the cable 5÷10mm)

  • process connection with G1/2 or M20x1,5 thread
  • connection head type aluminium XE-DANA (S1-standard), XE-DAND (S2),
    XE-DANAW (W1), XE-DANDW (W2) or stainless XE-BE (N1), IP65
  • sheath material: acid-resistant steel 1.4541
  • cable gland ATEX II GD IP65 (for cable 5÷10 mm)
  • Exi acc. to ATEX

price По запросу

Read more
Available

Available

Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M2 Ex d I Mb (with connection head NS) II 2G Ex d IIC T6 Gb II 2D Ex t IIIC T85ºC Db IP66

  • aluminium: XD-AD (AS1 – one cable gland, AS2 – two cable glands)
  • aluminium, cover with window: XD-ADwin (AS3 – one cable gland, AS4 – two cable glands)
  • stainless steel: XD-SD (NS1 – one cable gland, NS2 – two cable glands)
  • sheath material: acid-resistant steel 1.4541 or 1.7335
  • cable gland: ATEX II 2 GD; ATEX I M2; IP 66÷68, cable diameter: 3÷14,3 mm (standard 6,1÷11,7)
  • Exd acc. to ATEX

price По запросу

Read more
Available

Available

Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M1 Ex ia (with connection head N1) II 1/2G Ex ia IIC T6 II 1/2D Ex ia IIIC T85°C cable gland II 2GD Ex eb IIc, Ex ta IIIC (for the cable 5÷10mm)

  • process connection with G1/2 or M20x1,5 thread
  • connection head type aluminium XE-DANA (S1-standard), XE-DAND (S2),
    XE-DANAW (W1), XE-DANDW (W2) or stainless XE-BE (N1), IP65
  • sheath material: acid-resistant steel 1.4541
  • cable gland ATEX II GD IP65 (for cable 5÷10 mm)
  • Exi acc. to ATEX

price По запросу

Read more
Available

Available

Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M2 Ex d I Mb (with connection head NS) II 2G Ex d IIC T6 Gb II 2D Ex t IIIC T85ºC Db IP66

  • aluminium: XD-AD (AS1 – one cable gland, AS2 – two cable glands)
  • aluminium, cover with window: XD-ADwin (AS3 – one cable gland, AS4 – two cable glands)
  • stainless steel: XD-SD (NS1 – one cable gland, NS2 – two cable glands)
  • sheath material: acid-resistant steel 1.4541 flange PN16, DN20, DN25
  • cable gland: ATEX II 2 GD; ATEX I M2; IP 66÷68, cable diameter: 3÷14,3 mm (standard 6,1÷11,7)
  • Exd acc. to ATEX

price По запросу

Read more
Available

Available

Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M1 Ex ia (with connection head N1) II 2G Ex ia IIC T6 II 2D Ex ia IIIC T85°C cable gland II 2GD Ex eb IIc, Ex ta IIIC (for the cable 5÷10mm)

  • process connection with G1/2 or M20x1,5 thread
  • connection head type aluminium XE-DANA (S1-standard), XE-DAND (S2),
    XE-DANAW (W1), XE-DANDW (W2) or stainless XE-BE (N1), IP65
  • sheath material: acid-resistant steel 1.4541, 1.4841 or 1.4762
  • cable gland ATEX II GD IP65 (for cable 5÷10 mm)
  • Exi acc. to ATEX

price По запросу

Read more
Available

Available

Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M2 Ex d I Mb (with connection head NS) II 2G Ex d IIC T6 Gb II 2D Ex t IIIC T85ºC Db IP66

  • process connection with G1/2 or M20x1,5, 1/2NPT thread
  • aluminium: XD-AD (AS1 – one cable gland, AS2 – two cable glands)
  • aluminium, cover with window: XD-ADwin (AS3 – one cable gland, AS4 – two cable glands)
  • stainless steel: XD-SD (NS1 – one cable gland, NS2 – two cable glands)
  • sheath material: acid-resistant steel 1.4541
  • cable gland: ATEX II 2 GD; ATEX I M2; IP 66÷68, cable diameter: 3÷14,3 mm (standard 6,1÷11,7)
  • Exd acc. to ATEX

Db IP66

price По запросу

Read more
Available

Available

Temperature sensor suitable for measurement of liquid and gaseous media. Temperature sensor has ATEX approval for application in hazardous area: I M1 Ex ia (with connection head N1) II 2G Ex ia IIC T6 II 2D Ex ia IIIC T85°C cable gland II 2GD Ex eb IIc, Ex ta IIIC (for the cable 5÷10mm)

  • process connection with G1/2 or M20x1,5 thread
  • connection head type aluminium XE-DANA (S1-standard), XE-DAND (S2),
    XE-DANAW (W1), XE-DANDW (W2) or stainless XE-BE (N1), IP65
  • sheath material: acid-resistant steel 1.4541
  • cable gland ATEX II GD IP65 (for cable 5÷10 mm)
  • Exi acc. to ATEX

price По запросу

Read more
Available

Available

Temperature sensor suitable for measurement of liquid and gaseous media. Temperature sensor has ATEX approval for application in hazardous area: I M2 Ex d I Mb (with connection head NS) II 2G Ex d IIC T6 Gb II 2D Ex t IIIC T85ºC Db IP66

  • aluminium: XD-AD (AS1 – one cable gland, AS2 – two cable glands)
  • aluminium, cover with window: XD-ADwin (AS3 – one cable gland, AS4 – two cable glands)
  • stainless steel: XD-SD (NS1 – one cable gland, NS2 – two cable glands)
  • sheath material: acid-resistant steel 1.4541, 1.4571, 2.4816
  • cable gland: ATEX II 2 GD; ATEX I M2; IP 66÷68, cable diameter: 3÷14,3 mm (standard 6,1÷11,7)
  • Exd acc. to ATEX

price По запросу

Read more
Available

Available

Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M1 Ex ia (with connection head N1) II 1/2G Ex ia IIC T6 II 1/2D Ex ia IIIC T85°C cable gland II 2GD Ex eb IIc, Ex ta IIIC (for the cable 5÷10mm)

  • process connection with G1/2 or M20x1,5 thread
  • connection head type aluminium XE-DANA (S1-standard), XE-DAND (S2),
    XE-DANAW (W1), XE-DANDW (W2) or stainless XE-BE (N1), IP65
  • sheath material: boilert steel 1.4541
  • cable gland ATEX II GD IP65 (for cable 5÷10 mm)
  • Exi acc. to ATEX

price По запросу

Read more
Available

Available

Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M1 Ex ia (with connection head N1) II 1/2G Ex ia IIC T6 II 1/2D Ex ia IIIC T85°C cable gland II 2GD Ex eb IIc, Ex ta IIIC (for the cable 5÷10mm)

  • process connection with G1/2 or M20x1,5 thread
  • connection head type aluminium XE-DANA (S1-standard), XE-DAND (S2),
    XE-DANAW (W1), XE-DANDW (W2) or stainless XE-BE (N1), IP65
  • sheath material: stainless steel 1.4541
  • cable gland ATEX II GD IP65 (for cable 5÷10 mm)
  • Exi acc. to ATEX

price По запросу

Read more
Available

Available

Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M1 Ex ia (with connection head N1) II 1/2G Ex ia IIC T6 II 1/2D Ex ia IIIC T85°C cable gland II 2GD Ex eb IIc, Ex ta IIIC (for the cable 5÷10mm)

  • process connection with G1/2 or M20x1,5 thread
  • connection head type aluminium XE-DANA (S1-standard), XE-DAND (S2),
    XE-DANAW (W1), XE-DANDW (W2) or stainless XE-BE (N1), IP65
  • sheath material: acid-resistant steel 1.4541
  • cable gland ATEX II GD IP65 (for cable 5÷10 mm)
  • Exi acc. to ATEX

price По запросу

Read more
Available

Available

This sensor is used for temperature measurement of liquid and gaseous media. The temperature sensor design (replaceable measuring insert) is suitable for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the the bottom of the sensor thermowell.

  • Temperatura range -200÷550ºC RTD
  • sensing element: Pt100/Pt500/Pt1000 resistor
  • process connection with G1/2 or M20x1,5 thread
  • connection head type BA IP55, – 40÷100ºC
  • sheath material: acid-resistant steel 1.4541
  •  temperature transmitter can be mounted in a connection head
  • measuring insert: pipe or mineral insulated version

price По запросу

Read more
Available

Available

Temperature sensor with special sanitary flange connection Clamp type suitable for measurement in food and pharmaceutical industry. It has National Institute of Hygiene (PZH) attestation.

  • process connection fl ange Clamp acc. to PN-ISO 2852
  • connection head type MAA, BA; IP 54 -40÷100ºC
  • MBEG, BEG – material: stainless steel 1.4541, IP65, -40÷100°C
  • sheath material: acid-resistant steel 1.4541
  • National Institute of Hygiene (PZH) attestation

price По запросу

Read more
Available

Available

Temperature sensor suitable for measurement of pipes and shafts. Rigid (pipe) sheath is joined to radiator enhancing the area of heat reception. Sensor has a band clamp that enables permanent radiator installation on pipe or shaft. Temperature sensor has ATEX approval for application in hazardous area: II 2G Ex ia IIC T6 II 2D Ex ia IIIC T85°C

  • radiator enhancing surface of heat reception
  • band clamp for mounting on a pipeline
  • sheath material: brass

price По запросу

Read more
Available

Available