- radiator enhancing surface of heat reception with band clamp for mounting on a pipeline DN 15÷200 mm
- insulated hot junction SO
- material: brass
Products not found
Temperature sensor with handgrip and pointed tip suitable for measurement of various types of meat and cold meat . It has an attestation issued by National Institute of Hygiene(PZH) for usage in contact with food because of the special materials it is made of.This sensor is terminated with miniature plug that enables its connection to portable temperature meter TES.
- steel or tefl on hand grip
- suitable for food industry
- National Institute of Hygiene (PZH) attestation
- sheath material: acid-resistant steel 1.4541
Retail price from $52
Temperature sensor applied in industrial pipelines, pressure and other tanks for temperature measurement of liquids and gases. Sensing element is placed directly in the thermowell.
- Temperatura range -200÷150ºC RTD
- sensing element: Pt100/Pt500/Pt1000 resistor
- process connection with G1/2 or M20x1,5 thread
- connection head type MA IP54 – 40÷100ºC
- sheath material: acid-resistant steel 1.4541
- temperature transmitter can be mounted in a connection head
Retail price from $83
Sensor suitable for temperature measurement in district heating substations. Sensor with welded connector is applicable also for temperature measurement of liquid and gaseous media in high pressure conditions. Sensor consists of resistor placed in the thin-walled acid-resistant sheath connected to flexible lead protected with corrugated steel pipe.
- flexible protection hose, stainless,
- fiberglass insulation, metallic overbraid
- material: stainless steel 1.4541
Retail price from $45
Cable sensor can be equipped with plug for connection with portable temperature meters.
- performance with head MA
- PVC hand grip max. operating temperature 80°C
- with transmitter 4÷20 mA (LTT-03J)
- material: stainless steel 1.4541
Retail price from $69
Temperature sensor with handgrip and pointed tip suitable for measurement of various types of meat and cold meat . This stainless steel sensor has attestation issued by National Institute of Hygiene (PZH) for usage in contact with food.
- stainless steel 1.4541 hand grip
- suitable for food industry
- National Institute of Hygiene (PZH) attestation
- sheath material: acid-resistant steel 1.4541
Retail price from $45
Temperature sensor suitable for measurement in district heating substations. Applicable for temperature measurement of liquid and gaseous media in high pressure conditions. This sensor consists of sensing element placed in the thin-walled acid-resistant sheath with connector and flexible lead wire. Temperature sensor has ATEX approval for application in hazardous area: II 1
- movable threaded connector or nut
- thermocouple sensor with insulated hot junction
- sheath material: stainless steel 1.4541
price По запросу
Temperature sensor suitable for measurement of surface to which it is attached. On the bottom of plastic housing aluminium radiator is placed, transferring heat from the adjacent surface. Thermometric resistor is placed in the radiator. Optionally, sensor can be equipped with transmitter converting measured value to 4÷20mA current.
- tangent surface temperature measurement
- measuring plate
- housing: material polycarbonate, IP67
- material: aluminium
price По запросу
Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M2 Ex d I Mb (with connection head NS) II 2G Ex d IIC T6 Gb II 2D Ex t IIIC T85ºC Db IP66
- process connection with G1/2 or M20x1,5 thread
- aluminium: XD-AD (AS1 – one cable gland, AS2 – two cable glands)
- aluminium, cover with window: XD-ADwin (AS3 – one cable gland, AS4 – two cable glands)
- stainless steel: XD-SD (NS1 – one cable gland, NS2 – two cable glands)
- sheath material: acid-resistant steel 1.4541
- cable gland: ATEX II 2 GD; ATEX I M2; IP 66÷68, cable diameter: 3÷14,3 mm (standard 6,1÷11,7)
- Exd acc. to ATEX
price По запросу
Temperature sensor suitable for measurement of ambient temperature, mainly in industrial space like warehouses, production halls, etc. as well as under roofs and open spaces. It has an aesthetic housing made of plastic adequate for wall mounting and perforated sheath made of anodized aluminium. Optionally, sensor can be equipped with transmitter converting measured value to 4÷20mA current.
- perforated sheath
- humidity max. 85% RH
- housing: material polycarbonate, IP67
- material: stainless steel 1.4541
price По запросу
Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M2 Ex d I Mb (with connection head NS) II 2G Ex d IIC T6 Gb II 2D Ex t IIIC T85ºC Db IP66
- process connection with G1/2 or M20x1,5, 1/2NPT thread
- aluminium: XD-AD (AS1 – one cable gland, AS2 – two cable glands)
- aluminium, cover with window: XD-ADwin (AS3 – one cable gland, AS4 – two cable glands)
- stainless steel: XD-SD (NS1 – one cable gland, NS2 – two cable glands)
- sheath material: acid-resistant steel 1.4541
- cable gland: ATEX II 2 GD; ATEX I M2; IP 66÷68, cable diameter: 3÷14,3 mm (standard 6,1÷11,7)
- Exd acc. to ATEX
price По запросу
Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M2 Ex d I Mb (with connection head NS) II 2G Ex d IIC T6 Gb II 2D Ext IIIC T85ºC Db IP66
- aluminium: XD-AD (AS1 – one cable gland, AS2 – two cable glands)
- aluminium, cover with window: XD-ADwin (AS3 – one cable gland, AS4 – two cable glands)
- stainless steel: XD-SD (NS1 – one cable gland, NS2 – two cable glands)
- sheath material: acid-resistant steel 1.4541, 1.4841, 1.4762
- cable gland: ATEX II 2 GD; ATEX I M2; IP 66÷68,cable diameter: 3÷14,3 mm (standard 6,1÷11,7)
- Exd acc. to ATEX
price По запросу
Temperature sensor suitable for measurement of living quarters and office space, mainly in ventilation and air-conditioning systems. Flexible housing made of plastic is adequate for wall mounting. Optionally, sensor can be equipped with transmitter converting measured value to 4÷20mA current.
- without – unsheathed measuring resistor inside perforated housing
- humidity max. 85% RH
- material: ABS, IP-20
- mounting holes span 48 mm
price По запросу
Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M1 Ex ia (with connection head N1) II 1/2G Ex ia IIC T6 II 1/2D Ex ia IIIC T85°C cable gland II 2GD Ex eb IIc, Ex ta IIIC (for the cable 5÷10mm)
- process connection with G1/2 or M20x1,5 thread
- connection head type aluminium XE-DANA (S1-standard), XE-DAND (S2),
XE-DANAW (W1), XE-DANDW (W2) or stainless XE-BE (N1), IP65 - sheath material: acid-resistant steel 1.4541
- cable gland ATEX II GD IP65 (for cable 5÷10 mm)
- Exi acc. to ATEX
price По запросу
Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M2 Ex d I Mb (with connection head NS) II 2G Ex d IIC T6 Gb II 2D Ex t IIIC T85ºC Db IP66
- process connection with G1/2 or M20x1,5, 1/2NPT thread
- aluminium: XD-AD (AS1 – one cable gland, AS2 – two cable glands)
- aluminium, cover with window: XD-ADwin (AS3 – one cable gland, AS4 – two cable glands)
- stainless steel: XD-SD (NS1 – one cable gland, NS2 – two cable glands)
- sheath material: acid-resistant steel 1.4541, flange PN16, DN20. DN25
- cable gland: ATEX II 2 GD; ATEX I M2; IP 66÷68, cable diameter: 3÷14,3 mm (standard 6,1÷11,7)
- Exd acc. to ATEX
price По запросу
Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M1 Ex ia (with connection head N1) II 1/2G Ex ia IIC T6 II 1/2D Ex ia IIIC T85°C cable gland II 2GD Ex eb IIc, Ex ta IIIC (for the cable 5÷10mm)
- process connection with G1/2 or M20x1,5 thread
- connection head type aluminium XE-DANA (S1-standard), XE-DAND (S2),
XE-DANAW (W1), XE-DANDW (W2) or stainless XE-BE (N1), IP65 - sheath material: acid-resistant steel 1.4541
- cable gland ATEX II GD IP65 (for cable 5÷10 mm)
- Exi acc. to ATEX
price По запросу
Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M2 Ex d I Mb (with connection head NS) II 2G Ex d IIC T6 Gb II 2D Ex t IIIC T85ºC Db IP66
- aluminium: XD-AD (AS1 – one cable gland, AS2 – two cable glands)
- aluminium, cover with window: XD-ADwin (AS3 – one cable gland, AS4 – two cable glands)
- stainless steel: XD-SD (NS1 – one cable gland, NS2 – two cable glands)
- sheath material: acid-resistant steel 1.4541 or 1.7335
- cable gland: ATEX II 2 GD; ATEX I M2; IP 66÷68, cable diameter: 3÷14,3 mm (standard 6,1÷11,7)
- Exd acc. to ATEX
price По запросу
Temperature sensor suitable for measurement of pipes and shafts. Rigid sheath is joined to radiator enhancing the area of heat reception. Sensor has a band clamp that enables permanent radiator installation on pipe or shaft.
price По запросу
Temperature sensor suitable for measurement of outside temperature, both in places exposed to sun and not, mainly in air-conditioning and automation systems of district heating substations. Resistor is placed in a plastic housing. Optionally, sensor can be equipped with transmitter converting measured value to 4÷20mA current.
- closed-end sheath
- humidity max. 85% RH
- housing: material polycarbonate, IP67
- material: stainless steel 1.4541
price По запросу
Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M1 Ex ia (with connection head N1) II 1/2G Ex ia IIC T6 II 1/2D Ex ia IIIC T85°C cable gland II 2GD Ex eb IIc, Ex ta IIIC (for the cable 5÷10mm)
- process connection with G1/2 or M20x1,5 thread
- connection head type aluminium XE-DANA (S1-standard), XE-DAND (S2),
XE-DANAW (W1), XE-DANDW (W2) or stainless XE-BE (N1), IP65 - sheath material: acid-resistant steel 1.4541
- cable gland ATEX II GD IP65 (for cable 5÷10 mm)
- Exi acc. to ATEX
price По запросу
Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M2 Ex d I Mb (with connection head NS) II 2G Ex d IIC T6 Gb II 2D Ex t IIIC T85ºC Db IP66
- aluminium: XD-AD (AS1 – one cable gland, AS2 – two cable glands)
- aluminium, cover with window: XD-ADwin (AS3 – one cable gland, AS4 – two cable glands)
- stainless steel: XD-SD (NS1 – one cable gland, NS2 – two cable glands)
- sheath material: acid-resistant steel 1.4541 flange PN16, DN20, DN25
- cable gland: ATEX II 2 GD; ATEX I M2; IP 66÷68, cable diameter: 3÷14,3 mm (standard 6,1÷11,7)
- Exd acc. to ATEX
price По запросу
Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M1 Ex ia (with connection head N1) II 2G Ex ia IIC T6 II 2D Ex ia IIIC T85°C cable gland II 2GD Ex eb IIc, Ex ta IIIC (for the cable 5÷10mm)
- process connection with G1/2 or M20x1,5 thread
- connection head type aluminium XE-DANA (S1-standard), XE-DAND (S2),
XE-DANAW (W1), XE-DANDW (W2) or stainless XE-BE (N1), IP65 - sheath material: acid-resistant steel 1.4541, 1.4841 or 1.4762
- cable gland ATEX II GD IP65 (for cable 5÷10 mm)
- Exi acc. to ATEX
price По запросу
Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M2 Ex d I Mb (with connection head NS) II 2G Ex d IIC T6 Gb II 2D Ex t IIIC T85ºC Db IP66
- process connection with G1/2 or M20x1,5, 1/2NPT thread
- aluminium: XD-AD (AS1 – one cable gland, AS2 – two cable glands)
- aluminium, cover with window: XD-ADwin (AS3 – one cable gland, AS4 – two cable glands)
- stainless steel: XD-SD (NS1 – one cable gland, NS2 – two cable glands)
- sheath material: acid-resistant steel 1.4541
- cable gland: ATEX II 2 GD; ATEX I M2; IP 66÷68, cable diameter: 3÷14,3 mm (standard 6,1÷11,7)
- Exd acc. to ATEX
Db IP66
price По запросу
Temperature sensor suitable for measurement of liquid and gaseous media. Temperature sensor has ATEX approval for application in hazardous area: I M1 Ex ia (with connection head N1) II 2G Ex ia IIC T6 II 2D Ex ia IIIC T85°C cable gland II 2GD Ex eb IIc, Ex ta IIIC (for the cable 5÷10mm)
- process connection with G1/2 or M20x1,5 thread
- connection head type aluminium XE-DANA (S1-standard), XE-DAND (S2),
XE-DANAW (W1), XE-DANDW (W2) or stainless XE-BE (N1), IP65 - sheath material: acid-resistant steel 1.4541
- cable gland ATEX II GD IP65 (for cable 5÷10 mm)
- Exi acc. to ATEX
price По запросу
Temperature sensor suitable for measurement of liquid and gaseous media. Temperature sensor has ATEX approval for application in hazardous area: I M2 Ex d I Mb (with connection head NS) II 2G Ex d IIC T6 Gb II 2D Ex t IIIC T85ºC Db IP66
- aluminium: XD-AD (AS1 – one cable gland, AS2 – two cable glands)
- aluminium, cover with window: XD-ADwin (AS3 – one cable gland, AS4 – two cable glands)
- stainless steel: XD-SD (NS1 – one cable gland, NS2 – two cable glands)
- sheath material: acid-resistant steel 1.4541, 1.4571, 2.4816
- cable gland: ATEX II 2 GD; ATEX I M2; IP 66÷68, cable diameter: 3÷14,3 mm (standard 6,1÷11,7)
- Exd acc. to ATEX
price По запросу