Flow element, also known as differential pressure flow meter, consists of a primary detection piece (flow element) and a secondary device (differential pressure transmitter and flow indicator). Flow element is the most stable and reliable of all flow meters, which has a history of more than 100 years. Its wide applicability, high reliability and accurate accuracy make it widely used in the measurement of gas, liquid and vapor.

			int(9868)
NULL
		

Made in China. brand DDTOP, model LG Venturi

International delivery to United Arab Emirates, Kuwait, Qatar, Saudi Arabia, Saudi Arabia, Bahrain, Oman and other Middle Eastern countries.
Our warehouses are located in UAE.

price by request

Available

Available

Advantages

Only the best I&C brands

Our company is a UAE supplier of control and measuring instruments from well-known world brands

Advantages

Discounts for organisations

We sell high-tech equipment at best prices. We provide really advantageous conditions for partners

Advantages

Fast delivery across the Middle East

Supply to United Arab Emirates, Kuwait, Qatar, Saudi Arabia, Bahrain, Oman and other countries

Advantages

Professional advice on device selection

Our specialists are ready to advise you on any technical question. We can find an analogue of any device

Description of DDTOP LG Venturi

LG type venturi standard flow element has a long history and it is a widely used flow measuring instrument, with high accuracy, stable performance, low pressure loss (generally between 5% to 20% of the differential pressure value), easy to maintain, especially in the energy-saving work condition, it has the advantages of accurate measurement and reduced energy consumption, and has broad prospects in use.

Operating Principle

In the pipeline filled with single-phase continuous fluid, install a flow element (such as a venturi). When the fluid passes through the orifice of the flow element, the vapor forms a local contraction, the flow velocity increases, the kinetic energy increases, and the static pressure decreases.There is a static pressure difference between the front and back of the flow element, that is, ΔP = P1-P2. If the area of the orifice is F, the mass flow of the fluid is qm, the volume flow is qv, and the density is ρ, according to the principle of flow continuity and Bernoulli equation can derive the relationship between pressure difference and fluid flow:

In the formula, α is the flow coefficient. It can be seen from the above relationship that if the orifice area and fluid density are constant, the flow rate is proportional to the square root of the pressure difference, that is, as long as the pressure difference is measured, the flow rate can be calculated. The flow element measures the fluid flow rate based on this principle

Features

1.Structure is simple, easy to install, reliable to work, accuracy can meet the needs of engineering survey.

2.It has pure mechanical structure, according to the site high temperature and high pressure conditions to select appropriate structure and material. The highest pressure is 42 MPa and the highest temperature is 500℃.

3.Flow element has a long history of use, it has rich and reliable experimental data. Design and processing has been standardized. Standard orifice plate is no need to carry out the real flow calibration and maintenance.

Applications

  • Refining: Catalytic cracking, Acid-containing sedimentation tank, Hydrocracking, Coking, Isomerization, Crude oil desalination, Sulfur recovery, Catalytic reforming
  • Natural Gas: Light hydrocarbon recovery

 Technical specifications of DDTOP LG Venturi

  • Nominal diameter:DN50~DN250(classic venturi tube through machining shrinkage section)

DN300~DN1200(crude welded shrinkage section of iron plate)

  • Nominal pressure:0~42.0MPa
  • Aperture ratio:4≤β≤0.75(classic venturi tube through machining shrinkage section)

0.4≤β≤0.7(crude welded shrinkage section of iron plate)

  • Range ratio:1:10
  • Accuracy:±1%
  • Temperature:-196℃≤T≤+650℃

 How to buy DDTOP LG Venturi

1.  Model

Table 1 Flow Element Code and Meaning

Code Meaning Caliber
J Classic Venturi Tube Through Machining Shrinkage Section DN50-DN250
H Crude Welded Shrinkage Section Of Iron Plate More than DN250
Load More Items

Table 2 Tap Method and Meaning

Code Meaning
T Tap Equalizing Ring
Z Drilling Tap
Load More Items

Table 3 Nominal Diameter Code and Meaning

Code 01 016 02 026 03 04 05 06 08 10
DN mm 10 15 20 25 32 40 50 65 80 100
in 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 4
Code 12 15 20 25 30 35 40 45 50 60
DN mm 125 150 200 250 300 350 400 450 500 600
in 5 6 8 10 12 14 16 18 20 24
Code 70 80 90 100 105 110 115 120 125 130
DN mm 700 800 900 1000 1050 1100 1150 1200 1250 1300
in 28 32 36 40 42 44 46 48 50 52
Load More Items

Table 4 Nominal Pressure Code and Meaning

Code 01 02 03 04 05 06 10 11 15 16
PN MPa 1.6 2.0 2.5 4.0 5.0 6.3 10.0 11.0 15.0 16.0
Class 150 300 600 900
Code 26 42
PN MPa 26.0 42.0
Class 1500 2500
Load More Items

Table 5 Straight Pipe Section Code and Meaning

Code A B C D E F
Unit Flow Element Flow Element, Mounting Flange Flow Element,

Mounting Flange,

Upstream and downstream

straight pipe section

Flow Element,

Mounting Flange,

Upstream and downstream straight pipe section,

Upstream and downstream connection flange

Flow Element,

Mounting Flange,

Upstream and downstream straight pipe section,

Upstream connection flange

Flow Element,

Mounting Flange,

Upstream and downstream straight pipe section,

Downstream connection flange

Welding Structure
Load More Items
  1. Executive Standard

2.1 Flow Element Executive Standard

Code Meaning Standard Code
J Classic Venturi Tube Through Machining Shrinkage Section GB/T2624—2006(ISO5167—1—2003)
H Crude Welded Shrinkage Section Of Iron Plate GB/T2624—2006(ISO5167—1—2003)
Load More Items

For example, DN50 CL300 flange connection tap equalizing ring venturi tube model is LGJT-0505A.

2.2 Flange and Gasket Executive Standard

Flange and gasket standards can be selected from HG/T20592~20614-09 (European system) or HG/T20615~20635-09 (American system) or other standards

User Guide and Instruction manual for DDTOP LG Venturi

You can request the necessary certificates, documentation, instructions and user guide for DDTOP LG Venturi using the special form.

You can buy DDTOP LG Venturi in UAE at a favourable price in «Texair FZCO» by leaving a request on the website, by phone +441225535040 or by email . DDTOP LG Venturi price are subject to change depending on exchange rates. We deliver instruments by transport companies in United Arab Emirates, Kuwait, Qatar, Saudi Arabia, Saudi Arabia, Bahrain and other Middle Eastern countries.