DWYER PUF portable ultrasonic flowmeter kit

The Series PUF Portable Ultrasonic Flowmeter Kit utilizes the transit-time difference for measuring flow rates in pipes non-invasively. It is a compact and lightweight instrument incorporating the latest electronics and signal processing technologies, realizing high performance and easy operation. This device is capable of 20 hours continuous operation with its built-in battery. The PUF comes with an IP67 rated carrying case with molded foam inserts to hold and protect all equipment against dust and water. The screen offers easy to read text with a convenient backlight for visual comfort. The efficient layout of the function keys add to this unit’s easy to use programming. The unit comes with RS232 and USB connections to allow for easy connection to any personal computer or printer.

			int(5605)
NULL
		

Made in USA. brand DWYER, model PUF

International delivery to United Arab Emirates, Kuwait, Qatar, Saudi Arabia, Saudi Arabia, Bahrain, Oman and other Middle Eastern countries.
Our warehouses are located in UAE.

Retail price from $12576,25

Available

Available

Founded in 1931, DWYER manufactures equipment for measurement, conversion and control – pressure, temperature, level, flow.

Advantages

Only the best I&C brands

Our company is a UAE supplier of control and measuring instruments from well-known world brands

Advantages

Discounts for organisations

We sell high-tech equipment at best prices. We provide really advantageous conditions for partners

Advantages

Fast delivery across the Middle East

Supply to United Arab Emirates, Kuwait, Qatar, Saudi Arabia, Bahrain, Oman and other countries

Advantages

Professional advice on device selection

Our specialists are ready to advise you on any technical question. We can find an analogue of any device

Description of DWYER PUF

PRINCIPLES OF OPERATION
Two sensors are placed on the exterior of the pipe, and each transmits an ultrasonic pulse through the pipe and fluid to the other. The velocity of the liquid flowing through the pipes causes the pulse to accelerate or decelerate. The difference in the transit times of the two pulses is used to calculate the flow rate. The use of transit time allows the flowmeter to be unaffected by pressure or temperature changes.

Calibration Option available under Accessories. 

PRODUCT APPLICATIONS

  • Treated Water
  • River Water
  • Sea Water
  • Potable Water
  • Demineralized Water
  • Glycol/water mix
  • Hydraulic System
  • Diesel Oil

FEATURES

Kit Includes:

  • Converter
  • Set of Transducers (Both Sets for Model PUF-1001)
  • Transducer Holders
  • Set Transducer Cables (6.56 ft (2 m))
  • USB, RS232, 4 to 20 mA Communication Cables
  • 12 VDC Power Supply
  • Ultrasonic Coupling Grease
  • Set of Chains
  • Ruled Guide Rail
  • Test Block
  • Carrying Case

Technical specifications of DWYER PUF

  • Service: Homogeneous liquids that do not contain air bubbles capable of ultrasonic wave propagation.
  • Inputs: Lemo connector cable from sensors.
  • Range: 0.33 to 65.62 ft/s (0.1 to 20 m/s).
  • Display: 240 x 64 pixel graphic display, high contrast black on white with backlight; Languages: English, French, German, Swedish, Italian, Spanish, Portuguese, Russian, Norwegian, and Dutch; 5.2″ W x 1.5″ H (132.1 x 38.1 mm).
  • Accuracy: ± 0.5 to 2% of flow reading for flow rate > 0.66 ft/s (0.2 m/s) and Pipe ID > 3 in (75 mm). ± 3% of flow reading for flow rate > 0.66 ft/s (0.2 m/s) and Pipe ID in range 0.5 to 3 in (13 to 75 mm). ± 6% of flow reading for flow rate < 0.66 ft/s (0.2 m/s).
  • Power Requirements: 9 to 24 VDC; (1) 5-Cell NiMH battery, internal, factory replaceable (continuous operation time: 20 hours with back light and output off); (recharging time: 6.5 hours, power adapter used).
  • Power Consumption: 10.5 W.
  • Power Adapter: 110/240 VAC adapter; UK,US, European adapters included.
  • Temperature Limits: -4 to 275°F (-20 to 135°C).
  • Outputs: Analog: 1 opto-isolated output: 4 to 20 mA, 0 to 16 mA or 0 to 20 mA (selectable); Error current: 0 to 26 mA (selectable); Load resistance: 620 O max; Pulse: 1 opto-isolated MOSFET relay, 150 mA max, 500 pps max, 200 Hz max.
  • Serial Communications: USB; RS-232.
  • Enclosure Rating: Transducers: IP51; Carrying Case: IP67; Converter: IP54.
  • Materials: Flame retardant injection molded ABS plastic.
  • Repeatability: ±0.5 % of measured value or ±0.066 ft/s (0.02 m/s).
  • Electrical Connections: Multi-pin Lemo plugs.
  • Turbidity: <3% by volume of particulate content.
  • Permissible Air Content: <3% by volume.
  • Response Time: <500 ms.
  • Weight: Unit without accessories: 2.30 lb (1.06 kg); Unit with accessories in carrying case: 14.40 lb (6.52 kg).
  • Compliance: CE.

ADDITIONAL SPECIFICATIONS

  • Applicable Pipe Material: Carbon steel, SS, copper, UPVC/PVDF, concrete, galvanized steel, mild steel, glass, brass.
  • Applicable Pipe Lining: Rubber, glass, concrete, epoxy, steel, other*.
  • Pipe Wall Thickness: 0.04 to 3″ (1 to 75 mm).
  • Pipe Lining Thickness: < 1″ (< 25 mm).

How to buy DWYER PUF

Model Description Price
PUF-1001 Portable ultrasonic flowmeter Type A/B, 0.5 to 78″ (13 to 2000 mm) pipe size, transducers with data logger.
$13,803.00
PUF-1002 Portable ultrasonic flowmeter Type A, 0.5 to 4.5″ (13 to 115 mm) pipe size, transducers with data logger.
$12,576.25

Accessories for DWYER PUF

Model Description Price
A-186 Silicone based grease acoustic couplant, 3 oz. tube.
$21.20
NISTCAL-FU NIST traceable calibration certificate for ultrasonic flowmeters. NOTE: EQUAL CERTS WILL BE CHARGED PER UNITS PURCHASED.
$405.00

User Guide and Instruction manual for DWYER PUF

You can request the necessary certificates, documentation, instructions and user guide for DWYER PUF using the special form.

You can buy DWYER PUF in UAE at a price starting from 12576,25 $ in «Texair FZCO» by leaving a request on the website, by phone +441225535040 or by email . DWYER PUF price are subject to change depending on exchange rates. We deliver instruments by transport companies in United Arab Emirates, Kuwait, Qatar, Saudi Arabia, Saudi Arabia, Bahrain and other Middle Eastern countries.