+441225535040

Mon-Fri: 8:00 - 18:00 UAE

Email:

DWYER TTE explosion-proof rtd temperature transmitter

The Series TTE Explosion-Proof RTD Temperature Transmitter is the ideal product for hazardous temperature measurement applications. The TTE series has seven preprogrammed temperature ranges that are selectable via an internal dip switch. For those applications that need a custom range, the transmitter can be easily configured for any range between -30 to 250°F with a minimum span of 40°F. The span and zero can be quickly adjusted with a simple push button design. The compact housing allows for the transmitter to be mounted in virtually any application.

			int(4881)
NULL
		

Made in USA. brand DWYER, model TTE

International delivery to United Arab Emirates, Kuwait, Qatar, Saudi Arabia, Saudi Arabia, Bahrain, Oman and other Middle Eastern countries.
Our warehouses are located in UAE.

Retail price from $644.8

Available

Available

Founded in 1931, DWYER manufactures equipment for measurement, conversion and control – pressure, temperature, level, flow.

Advantages

Only the best I&C brands

Our company is a UAE supplier of control and measuring instruments from well-known world brands

Advantages

Discounts for organisations

We sell high-tech equipment at best prices. We provide really advantageous conditions for partners

Advantages

Fast delivery across the Middle East

Supply to United Arab Emirates, Kuwait, Qatar, Saudi Arabia, Bahrain, Oman and other countries

Advantages

Professional advice on device selection

Our specialists are ready to advise you on any technical question. We can find an analogue of any device

Description of DWYER TTE

PRODUCT APPLICATIONS

  • Explosive process environments
  • Offshore HVAC monitoring

FEATURES

  • FM approved for Class I, Groups B, C, D; Class II, Groups E, F, G classified explosive environments
  • Optional LCD
  • Output span selected from seven common ranges or user determined

Technical specifications of DWYER TTE

  • Temperature Sensor: Pt1000, 0.00385 DIN.
  • Output Temperature Ranges: User selectable – any range between -30 to 250°F with a minimum span of 40°F.
  • Temperature Limits: Ambient: -4 to 158°F (-20 to 70°C); Process: -30 to 250°F (-34.4 to 120°C).
  • Accuracy: Transmitter: ±0.1% FS; Probe: ±0.3% FS.
  • Thermal Drift Effects: ±0.02%/°C max.
  • Response Time: 250 ms.
  • Wetted Materials: 316 SS.
  • Process Connection: 1/2″ male NPT or 1/2 male BSPT.
  • Conduit Connection: 1/2″ female NPT or M20.
  • Probe Length: 2″ to 18″ (depending on model).
  • Pressure Limits: 2000 psi (137.9 bar).
  • Power Requirements: 10 to 35 VDC.
  • Output Signal: 4 to 20 mA (two wire loop powered).
  • Optional Display: 2 lines X 8 character LCD.
  • Enclosure Rating: Weatherproof NEMA 4X (IP66) and Explosion-proof. Listed with FM for Class I, Division 1, Groups B, C and D, and dust ignition-proof for Class II, Division 1, Groups E, F and G and Class III atmospheres.
  • ATEX Certified: CE 2813 (Ex) II 2 G Ex db IIC T6…T4, Gb CE (Ex) 2813 II 1 D Ex ta IIIC T111°C Da, T6 Process Temp =80°C, Temperature Class T5 Process Temp =95°C, Temperature Class T4 Process Temp =120°C as defined on nameplate. EU-type Cerificate No.: EMT17ATEX0021 X. ATEX Standards: EN IEC 60079-0, EN 60079-1, EN 60079-31.
  • IECEx Certified: For Ex db IIC T6 Gb, Ex ta IIIC T111°C Da, Process Temp =80°C, Temperature Class T5 Process Temp =95°C, Temperature Class T4 Process Temp =120°C as defined on nameplate.
  • IECEx Certificate of Conformity: Element IECEx EMT 17.0007X; IECEx Standards: IEC 60079-0, IEC 60079-1, IEC 60079-31.
  • UKCA Ex Certified for: UKCA 0518 Ex II 2 G Ex db IIC T6…T4 Gb / II 1 D Ex ta IIIC T111°C Da, T6 process temp ≤ 80°C, T5 process temp ≤ 95°C, T4 process temp ≤ 120°C. UKCA Ex Certificate of Conformity: EMA22UKEX0066X. UKCA Ex Standards: EN IEC 60079-0, EN 60079-1, EN 60079-31.
  • Weight: 2 lb 8 oz (1134 g).
  • Compliance: ATEX, CE, FM, IECEx, UKCA Ex.

How to buy DWYER TTE

Model Description Price
TTE-104-W Explosion-proof RTD temperature transmitter, 4″ probe.
$644.80
TTE-104-W-LCD Explosion-proof RTD temperature transmitter, 4″ probe, with LCD display.
$815.35
TTE-106-W Explosion-proof RTD temperature transmitter, 6″ probe.
$644.80
TTE-106-W-LCD Explosion-proof RTD temperature transmitter, 6″ probe, with LCD display.
$815.35
TTE-109-W Explosion-proof RTD temperature transmitter, 9″ probe.
$686.90
TTE-109-W-LCD Explosion-proof RTD temperature transmitter, 9″ probe, with LCD display.
$857.45
TTE-112-W Explosion-proof RTD temperature transmitter, 12″ probe.
$686.90
TTE-112-W-LCD Explosion-proof RTD temperature transmitter, 12″ probe, with LCD display.
$857.45
TTE-115-W Explosion-proof RTD temperature transmitter, 15″ probe.
$729.05
TTE-115-W-LCD Explosion-proof RTD temperature transmitter, 15″ probe, with LCD display.
$899.60
TTE-118-W Explosion-proof RTD temperature transmitter, 18″ probe.
$729.05
TTE-118-W-LCD Explosion-proof RTD temperature transmitter, 18″ probe, with LCD display.
$899.60
Load More Items

Accessories for DWYER TTE

Model Description Price
A-287 Mounting bracket for pipe or surface mounting (includes bracket and two 2″ U-bolts)
$59.85
Load More Items

Model Chart DWYER TTE

 TTE-XX-W-OPT    TTE TEMPERATURE TRANSMITTER
     
        1ST SYMBOL (1ST X) AGENCY APPROVAL
           1     FM EXPLOSION PROOF
           2     ATEX/IECEX FLAMEPROOF
             
        2ND SYMBOL (2ND X) WELL PROBE LENGTH
           02    2 IN PROBE
           04    4 IN PROBE
           06    6 IN PROBE
           09    9 IN PROBE
           12    12 IN PROBE
           15    15 IN PROBE
           18    18 IN PROBE
             
        OPTION (OPT)
          -BSPT  3/4 IN BSPT PROCESS CONNECTION (STD IS NPT)
          -C5    C5M HOUSING PAINT SPECIFIICATION
          -LCD   LCD DISPLAY
          -M20   FEMALE M20 THD ELECTRICAL CONNECTION (STD IS NPT)

User Guide and Instruction manual for DWYER TTE

You can request the necessary certificates, documentation, instructions and user guide for DWYER TTE using the special form.

You can buy DWYER TTE in UAE at a price starting from 644.8 $ in «Texair FZCO» by leaving a request on the website, by phone +441225535040 or by email . DWYER TTE price are subject to change depending on exchange rates. We deliver instruments by transport companies in United Arab Emirates, Kuwait, Qatar, Saudi Arabia, Saudi Arabia, Bahrain and other Middle Eastern countries.