FC2000-TBIAH is a multi-function flow computer, which can be adapted to a variety of flow meters and the medium under test, and has a variety of functions, such as full flow parameter dynamic compensation, historical data storage, metering supervision, trade settlement, and network communication, so as to achieve volume and mass flow measurement. Especially in the support of standard nozzle flow meter measurement of natural gas has the support of wide range (double differential), remote assignment, energy measurement and other functions.
Made in China. brand DDTOP, model Flow Computer
International delivery to United Arab Emirates, Kuwait, Qatar, Saudi Arabia, Saudi Arabia, Bahrain, Oman and other Middle Eastern countries.
Our warehouses are located in UAE.
price by request
Available
Only the best I&C brands
Our company is a UAE supplier of control and measuring instruments from well-known world brands
Discounts for organisations
We sell high-tech equipment at best prices. We provide really advantageous conditions for partners
Fast delivery across the Middle East
Supply to United Arab Emirates, Kuwait, Qatar, Saudi Arabia, Bahrain, Oman and other countries
Professional advice on device selection
Our specialists are ready to advise you on any technical question. We can find an analogue of any device
FC2000-TBIAH is a multi-functional flow computer in FC2000 series products, which can be adapted to a variety of flow meters and the measured medium. It has a variety of functions, such as dynamic compensation of the full parameters of flow, historical data storage, measurement supervision, trade settlement, and network communication, etc. It can achieve volume and mass flow measurement. Especially in support of the standard nozzle flowmeter to measure natural gas, it has the function of wide range (double differential), remote assignment, energy measurement, etc.
Features
FC2000-TBIAH has flexible software and hardware platform, which can realize special function application for users. Multi CPU structure with 32-bit ARM processor as the core is adopted to ensure the accuracy and real-time of the calculation. 24-bit A/D converter with the base source inside is used to improve the accuracy of analog signal acquisition. All input, output signals and communication interfaces are completely isolated, and the reliability of the whole machine is improved.
FC2000-TBIAH flow calculation software has been certified by the state authority. FC2000-TBIAH flow calculation is one of FC2000 series of flow computers. FC2000 series of flow computer products also include FC2000-TBIAD single flow computer, FC2000-TBIAD (G) two-way wall hanging flow computer, FC2000-TBIAE、FC2000-TBIAE (M), FC2000-TBIAE (G) flow calculation conversion unit, etc.
Applications
Natural gas, artificial gas, superheated vapor, saturated vapor, general gas, water, hot water, liquid (oil, chemical products), etc.
Processors | 32-bit ARM processors |
Memory | On-board FLASH, SRAM, FRAM multiple memory, up to 32MB |
A/D Converter | 24-bit high-resolution A/D with internal reference source |
Display | 5.0″ 65K Color True Color LED Backlight TFT LCD |
Buttons | 5 buttons |
Local input signal | Six channel fully isolated 4~20mA analog signal |
Two pulses (0.2Hz~10.0KHz, 4~11V), configurable as voltage pulse, current pulse, open collector pulse, NAMUR standard pulse, with DC24V and DC12V power supply options. | |
Two way Pt100 RTD signal (-50℃~500℃) or 2 way thermocouple signal (with K, S, B, J, R, N, E, T multiple thermocouple options) | |
One channel HART protocol digital signal, support temperature, pressure, differential pressure transmitters. | |
Local output signal | 2 channels fully isolated 4~20mA analog signal output |
Uncertainty | 4-20mA conversion uncertainty: ±0.1% |
Pt100 RTD conversion uncertainty: ±0.1% | |
Thermocouple Conversion Uncertainty: ±0.2% | |
4-20mA output conversion uncertainty: ±0.1% | |
Calculation uncertainty: 0.05% | |
Maximum cumulative display | 999,999,999 Engineering units |
Communication interface | 1 RS232/RS485 interface |
1 10M/100M network card interface (optional) | |
1 RS485 interface | |
1 HART protocol interface | |
External power supply | 6-channel fully isolated DC24V/0.03A |
Data retention time | 10 years |
Working power | 220VAC±10%,50Hz、Power:25W |
Working conditions | Ambient temperature -20~55℃, relative humidity less than 85%. |
External dimensions | 144L x 144 H x 270W (mm) |
Mounting Type | Disc Horizontal Mounted |
Aperture size | 138W x 138H (mm)
Note: For the original 150W x 150H (mm) aperture, special mounting brackets can be provided without |
Model | Basic Codes | Additional codes | Description |
FC2000-TBIAH | Multiple Flow Computers | ||
FC2000-TBIAH(G) | Enhanced Multiple Flow Computers | ||
Software Versions | /ZTY | Version for steam, general purpose gas and liquid | |
/TRQ | Version for natural gas | ||
/ ZY | Version for dedicated software | ||
Additional functions | /C1 | HART protocol communication interface | |
/C2 | Serial Interface 1 RS485 | ||
/C3 | Serial Interface 2 RS232 | ||
/C4 | Serial Interface 2 RS485 | ||
/N2 | LAN communication function | ||
/FA | 4~20mA flow signal output | ||
/EX4 | Expanded to 4 flows | ||
Mounting Type | /H | Disk mounted horizontal |
Note:
Only three of C1/C2/C3/C4 can be selected from the additional functions, and C3 and C4 cannot be selected at the same time.
You can request the necessary certificates, documentation, instructions and user guide for DDTOP Flow Computer using the special form.
You can buy DDTOP Flow Computer in UAE at a favourable price in «Texair FZCO» by leaving a request on the website, by phone +441225535040 or by email ceo@texair.eu. DDTOP Flow Computer price are subject to change depending on exchange rates. We deliver instruments by transport companies in United Arab Emirates, Kuwait, Qatar, Saudi Arabia, Saudi Arabia, Bahrain and other Middle Eastern countries.
See also: Flow meters