+971 56 389 7151

Mon-Fri: 8:00 - 18:00 UAE

Email:

Michell Optidew Industrial Grade Chilled Mirror Hygrometer

Drift-Free Affordable Humidity Measurement for Industrial Applications

  • New chilled mirror hybrid sensor gives fast dynamic response to changes in humidity
  • Accurate to ±0.15°C dew point, ±0.1°C temperature
  • Wide measurement range from -40 to +120°C dew point
  • Choice of communication methods, including Modbus TCP over Ethernet communication for easy networking
  • Optional pressure transmitter for accurate calculation of ppmV & g/kg
			int(20950)
NULL
		

Made in United Kingdom. brand Michell, model Optidew

International delivery to United Arab Emirates, Kuwait, Qatar, Saudi Arabia, Saudi Arabia, Bahrain, Oman and other Middle Eastern countries.
Our warehouses are located in UAE. Delivery to other countries (Europe, North and South America, Asia, Africa) is discussed individually.

price По запросу

Available

Available

Advantages

Only the best I&C brands

Our company is a UAE supplier of control and measuring instruments from well-known world brands

Advantages

Discounts for organisations

We sell high-tech equipment at best prices. We provide really advantageous conditions for partners

Advantages

Fast delivery across the Middle East

Supply to United Arab Emirates, Kuwait, Qatar, Saudi Arabia, Bahrain, Oman and other countries

Advantages

Professional advice on device selection

Our specialists are ready to advise you on any technical question. We can find an analogue of any device

Description of Michell Optidew

The Optidew 401 and Optidew 501 are fast-responding chilled mirror hygrometers utilizing the latest developments in chilled mirror technology. Ideal for use in industrial humidity control and precision laboratory applications. Available in bench top and wall mount configurations as well as a transmitter version of the Optidew 501 (without a display). Featuring ±0.15 °C accuracy across its -40 to +120 °C dew-point measurement range.

Applications

  • Reference humidity instrument for climatic and environmental chambers
  • Inlet air measurement for engine testing
  • HVAC testing
  • Environmental monitoring in clean rooms
  • Coating process monitoring – for confectionary and pharmaceuticals
  • Control of humidity for metallurgical processes

Technical specifications of Michell Optidew

Performance
Dew Point Measurement Accuracy ±0.15°C (±0.27°F)
Repeatability ±0.05°C (±0.09°F)
Sensitivity ±0.01°C (±0.018°F)
Response Stable measurement at +10°C (+50°F) dp within 1 minute
Dew-Point Sensor
Sensor Single Stage Dual Stage Harsh Environment
Dew Point Range (°C) -25…+90°C (-13…+194°F) -40…+90°C (-40…+194°F) -40…+120°C (-40…+248°F)
Temperature Range (°C) -40…+90°C (-40…+194°F) -40…+90°C (-40…+194°F) -40…+120°C (-40…+248°F)
% rh Range @ 23°C 2.25…100% rh 0.45…100% rh 0.45…100% rh
Material POM (head) Aluminum (body) POM (head) Aluminum (body) PEEK (head) Aluminum (body)
Corrosion & Saturation Protection Active Component Isolation System
Mirror Temperature Measurement Pt1000, Class A
Recommended Sample Flow Ambient (environmental measurements) to 2Nl/min (flowing sample)
Pressure 2500 kPa max
Process Connection M36x1.5
Remote PRT
Temperature Measurement Accuracy ±0.1°C (±0.18°F)
Temperature Measurement Pt100, Class A
Cables
Cable Length 0.3, 3, 5, 10, and 20m (11.81”, 9.84, 16.4, 32.81, and 65.62 ft) lengths available (cables can be combined)
Minimum Operating Temperature Standard: -25°C (-13°F) High temperature: -40°C (-40°F)
Maximum Operating Temperature Standard: +90°C (+194°F) High temperature: +120°C (+248°F)
Remote Pressure Sensor (Optional)
Pressure Measurement Accuracy ±0.25% FS
Pressure Measurement Range 0-160 kPa OR 0-2500 kPa
Process Connection 1/8” NPT-M
Control Unit
Resolution 1 or 2 decimal places selectable
Measurement Units °Cdp or °Fdp, Relative humidity – %, Absolute humidity – g/m3, ppmV, Mixing Ratio – g/kg, Wet Bulb Temperature (Twb) – °C, °F, Water Vapor Pressure (wvp) – Pa, Ambient Temperature – °C, °F, Pressure converted DP – °C, °F, Pressure – kPa, Bara, Barg, Psia, Psig
Enclosure Wall Mount – Optidew 501 Bench Top – Optidew 401
Material ABS
Analog Outputs Two 0/4–20 mA outputs (maximum load 500Ω)
Digital Communications Modbus RTU over RS485 (standard)
Modbus TCP over Ethernet (optional)
Modbus RTU over: USB (standard) RS485 (standard)
Modbus TCP over Ethernet (optional)
Alarms 1x Process Relay, 1x Alarm Relay, Both Form C, 1A, 30 V dc
Inputs 4–20 mA for pressure sensor
Data Logging SD card slot (optional) SD card slot (standard)
Ingress Protection IP54 (standard), IP65 (optional) IP54
Dimensions 220 x 175 x 75 mm (8.66” x 6.89” x 3”) 220 x 175 x 118 mm (8.66” x 6.89” x 4.65”)
Weight Control unit: 1.5 kg (3.3 lb), Sensor: 200 g (7.05 oz)
Display 5.7” color touch screen (optional) 5.7” color touch screen
Environmental Conditions -20…+50°C (-4…+122°F), up to 100% rh non-condensing (optional) 100% rh condensing with IP65 connector version
Supply Voltage 100…240 V AC, 50…60 Hz
Power Consumption 30 VA max
Expand Table

User Guide and Instruction manual for Michell Optidew

You can request the necessary certificates, documentation, instructions and user guide for Michell Optidew using the special form.

You can buy Michell Optidew in UAE at a price starting from По запросу $ in «Texair FZCO» by leaving a request on the website, by phone +441225535040 or by email . Michell Optidew price are subject to change depending on exchange rates. We deliver instruments by transport companies in United Arab Emirates, Kuwait, Qatar, Saudi Arabia, Saudi Arabia, Bahrain and other Middle Eastern countries.

Generate an article by selecting the parameters below
Article:
Quantity:
-
+
Clear
I know the article / Need help
Get Offer
The article is not fully generated. Please double-check the selected values.