Michell S8000 -100 High Precision Chilled Mirror Hygrometer

The New Laboratory Humidity Reference Standard

  • Accuracy of ±0.1 °C (±0.18 °F)
  • Precision measurement to -100 °C (-148 °F) frost point (13.8 ppbV) with no need for additional cooling
  • Reproducibility of ±0.15 °C (±0.27 °Ffp) at -100 °C (-148 °Ffp) frost point
  • Simple configuration and operation via touch screen interface
  • Sensor optimized for fast response to low moisture levels
  • External 4-wire Pt100 connections
  • Microscope for visual inspection of condensate on mirror
  • Compact 19” x 4U package for flexibility of installation
  • Ethernet or USB connections
  • SD card data logging
			int(20909)
NULL
		

Made in United Kingdom. brand Michell, model S8000 -100

International delivery to United Arab Emirates, Kuwait, Qatar, Saudi Arabia, Saudi Arabia, Bahrain, Oman and other Middle Eastern countries.
Our warehouses are located in UAE. Delivery to other countries (Europe, North and South America, Asia, Africa) is discussed individually.

price По запросу

Available

Available

Advantages

Only the best I&C brands

Our company is a UAE supplier of control and measuring instruments from well-known world brands

Advantages

Discounts for organisations

We sell high-tech equipment at best prices. We provide really advantageous conditions for partners

Advantages

Fast delivery across the Middle East

Supply to United Arab Emirates, Kuwait, Qatar, Saudi Arabia, Bahrain, Oman and other countries

Advantages

Professional advice on device selection

Our specialists are ready to advise you on any technical question. We can find an analogue of any device

Description of Michell S8000 -100

The S8000 -100 hygrometer directly measures the formation of condensation on a mirrored surface, offering the widest possible measurement range of -100…+20 °C frost/dew point. It uses a unique advanced dual optics system which detects small changes in moisture condensed on the mirror surface. This results in a very high sensitivity and fast response to changes in frost point, even at very low moisture levels where measurements are most challenging. Fully automated control of the system means that no operator intervention is required. The instrument provides a range of Modbus digital communications, and analog outputs allowing it to be monitored remotely or via specific S8000 -100 logging software. 4-wire Pt100 connections are provided on the rear panel for remote mirror temperature monitoring. A high-contrast touch-screen LCD display gives or presents entirely customizable local indication of the measured values, along with a trend graph and fault warnings.

Applications

  • Reference humidity measurements in standards laboratories
  • Reference instrument in humidity calibration facilities
  • Precision moisture measurements in research and development

Technical specifications of Michell S8000 -100

Dew-Point Sensor
Measurement Range -100…+20 °C (-148…+68 °F) frost/dew point
Measurement Accuracy* ±0.1 °C (±0.18 °F)
Reproducibility at -100 °Cfp (-148 °Ffp) ±0.15 °C (±0.27 °F)
Stability at -100 °Cfp (-148 °Ffp) ±0.05 °C (±0.09 °F)
Speed of Response <2 hours to ±0.25 °C (±0.45 °F) stability @ -90 °Cfp (-130 °Ffp)
<6 hours to ±0.25 °C (±0.45 °F) stability @ -100 °Cfp (-148 °Ffp)
Temperature Dependence at -100 °C (-148 °F) ±0.15 °Cfp (±0.27 °Ffp) per 1 °C (1.8 °F) environmental temperature change
Mirror Gold-plated copper
Temperature Measurement 4-wire Pt100, 1/10 DIN class B
Sample Flow Rate 500…1000 ml/min (recommended 750 ml/min)
Sample Gas Pressure 1.6 bara (23.2 psia) max.
Pressure Sensor
Measurement Range 0…1.6 bara (23.2 psia)
Measurement Accuracy Accuracy 0.25% FS
Typical thermal error 1.5% FS
Typical drift 0.2% FS/p.a non-cumulative
Temp Comp -20 °C…+80 °C (-4 °F…+176 °F)
Flow Sensor
Measurement Range 0 to 1000 ml/min
Measurement Accuracy ±1.5% FS (10…100% of rated flow)
Expand Table

* Measurement accuracy means maximum deviation between instrument under
test and corrected reference. To this must be added the uncertainties associated
with the calibration system and the environmental conditions during testing or
subsequent use.

Monitor
Resolution User selectable to 0.001 °C (0.0018 °F), depending on parameter
Measurement Units °C dew/frost point, °C temperature, ml/min flow, bara pressure
Calculated Units Relative humidity – %, Absolute humidity – g/m³, ppmV, Mixing Ratio – g/kg, Wet Bulb Temperature (Twb) – °C, °F, Water Vapor Pressure (wvp) – Pa, Pressure converted DP – °C, °F, Pressure – kPa, Barg, Psia, Psig
Outputs Analog: 2x active mA outputs, configurable 0…20 mA or 4…20 mA
Digital: Modbus RTU over USB and optionally Modbus RTU over RS485/RS232, or Modbus TCP over Ethernet
Alarm: 1x Process Relay, 1x Alarm Relay, both Form C, 1 A, 30 V DC
User Interface 5.7” LCD with touchscreen
Data Logging SD Card (8GB supplied) and USB interface. Supports SD Card (FAT-32) – 32 GB max. that allows 24 million logs or 560 days, logging at 2-second intervals
Environmental Conditions +5 °C…+30 °C (+41 °F…+86 °F)
Power Supply 85…264 V AC
Power Consumption 185 VA
Mechanical Specification
Dimensions (W x H x D) 440 mm x 185 mm x 430 mm (17.32” x 7.28” x 16.93”)
Weight 21.5 kg (47.4 lb)
Sample Gas Connections Inlet: ¼” VCR
Outlet: ¼” Swagelok tube
General
Optional Remote Temperature Probe 4-wire Pt100, 1/10 DIN class B, 2m cable
Calibration 5-point UKAS calibration to -90 °Cfp (-130 °Ffp) or to -80 °Cfp (-112 °Ffp)
Expand Table

User Guide and Instruction manual for Michell S8000 -100

You can request the necessary certificates, documentation, instructions and user guide for Michell S8000 -100 using the special form.

You can buy Michell S8000 -100 in UAE at a price starting from По запросу $ in «Texair FZCO» by leaving a request on the website, by phone +441225535040 or by email . Michell S8000 -100 price are subject to change depending on exchange rates. We deliver instruments by transport companies in United Arab Emirates, Kuwait, Qatar, Saudi Arabia, Saudi Arabia, Bahrain and other Middle Eastern countries.

Generate an article by selecting the parameters below
Article:
Quantity:
-
+
Clear
I know the article / Need help
Get Offer
The article is not fully generated. Please double-check the selected values.