+971 56 389 7151

Mon-Fri: 8:00 - 18:00 UAE

Email:

Michell Pura Ultra-Pure Moisture Hygrometer

Hygrometers For Trace Moisture in Pure Gases

  • Measures down to -120 °Cdp (-184 °Fdp) (1 ppbV)
  • Stable and repeatable measurement
  • Fast response
  • Economical and advanced monitor solutions
  • Dew-point or moisture content output
  • 4…20 mA and Modbus RTU over RS485 outputs
  • Traceable 7-point calibration certificate
  • 1/2”, 1/4” male VCR process connections
  • MiniDIN 43650 C, M12 electrical connectors
  • Optional hazardous area approval
  • Service exchange program
			int(20741)
NULL
		

Made in United Kingdom. brand Michell, model Pura

International delivery to United Arab Emirates, Kuwait, Qatar, Saudi Arabia, Saudi Arabia, Bahrain, Oman and other Middle Eastern countries.
Our warehouses are located in UAE. Delivery to other countries (Europe, North and South America, Asia, Africa) is discussed individually.

price По запросу

Available

Available

Advantages

Only the best I&C brands

Our company is a UAE supplier of control and measuring instruments from well-known world brands

Advantages

Discounts for organisations

We sell high-tech equipment at best prices. We provide really advantageous conditions for partners

Advantages

Fast delivery across the Middle East

Supply to United Arab Emirates, Kuwait, Qatar, Saudi Arabia, Bahrain, Oman and other countries

Advantages

Professional advice on device selection

Our specialists are ready to advise you on any technical question. We can find an analogue of any device

Description of Michell Pura

These small, rugged pure gas moisture sensor/hygrometers are an ideal economical solution for moisture breakthrough indication in ultra-dry moisture purification applications.

The Pura is easy to install and use, for a wide variety of pure gas measurement applications. A service exchange program is also available, reducing the cost of maintenance.

Applications

  • Gas purification systems
  • Semiconductor manufacture
  • Pure gases
  • Fibre optic production
  • Optical coating processes
  • Electronic component manufacture
  • Speciality gas production and distribution

Technical specifications of Michell Pura

Product Pura 2-wire, 3-wire & Digital Transmitters Pura I.S. Transmitter
Performance Specifications
Measurement Range -120…-40 °Cdp (-184…-40 °Fdp); non-standard ranges available on request
Accuracy ±1 °C from -40 to -60 °Cdp (±1.8 °F from -40 to -76 °Fdp)
±2 °C from -60 to -100 °Cdp (±3.6 °F from -76 to -148 °Fdp)
±4 °C from -100 to -120 °Cdp (±7.2 °F from -148 to -184 °Fdp) (extrapolated)
Calibration Traceable 7-point calibration certificate
Electrical Specifications
Output Signal 4…20 mA (2-wire connection, current source)
4…20 mA (3-wire connection, current sink)
Pura M12: Modbus RTU over RS485
Pura 3-wire PUR-AOL-SEN-D: Michell Mnet digital
4…20 mA (2-wire connection, current source)
Output Dew point or moisture content (ppmV, ppbV)
Analog Output Scaled Range Dew point: -120…-40 °C (-184…-40 °F); Moisture content in gas: 0…127 ppmV
Supply Voltage Pura 2-wire/3-wire & Pura I.S.: 12…28 V DC
Pura M12: 5…28 V DC (digital)*
Load Resistance Max 250 Ω @ 14 V (500 Ω @ 24 V)
Current Consumption 23 mA max, depending on output signal
Compliances CE & UKCA
Operating Specifications
Operating Temperature -40…+60 °C (-40…+140 °F)
Compensated Temperature Range -20…+50 °C (-4…+122 °F)
Storage Temperature -40…+60 °C (-40…+140 °F)
Operating Pressure Minimum 10-7 Pa (10-9 torr); Maximum 24 MPa (240 barg / 3481 psig)
Flow Rate 1…5 Nl/min mounted in standard sampling block; 0…10 m/sec direct insertion
Mechanical Specifications
Ingress Protection IP66 in accordance with standard BS EN 60529:1992; NEMA 4 protection in accordance with standard NEMA 250–2003
Pura M12: IP65
Intrinsically Safe Area Certificates ATEX/UKCA: II 1 G Ex ia IIC T4 Ga (-20…+70 °C)
IECEx: Ex ia IIC T4 Ga (-20…+70 °C)
TR CU: 0Ex ia IIC T4 Ga (-20…+70 °C)
cQPSus: Class I, Division 1, Groups A, B, C & D, T4 Class I, Zone 0, AEx ia IIC T4 Ga, Ex ia IIC T4 Ga Tamb +70 °C
Housing Material 316 stainless steel
Dimensions Please refer to the dimensional drawings on page 4 of this datasheet
Packaging Pura Premium: Double bagged and sealed in UHP inert gas
Pura OEM and Pura Sensor: Single bagged in 1000 gauge polythene
All options: Shipped individually in a profiled cardboard carton
Sensor version supplied with protective guard over sensor technology for transportation and handling
Process Connection Pura Premium (PRM): 2 x 1/4” male VCR
Pura OEM (OEM): 2 x 1/4” male VCR
Pura Sensor (SEN): 1/2” male VCR
Weight PRM and OEM versions: 450 g (0.99 lb)
SEN version: 180 g (0.4 lb)
Electrical Connections Pura: MiniDIN 43650 form C
Pura M12: M12 5 Pin (A coded)
MiniDIN 43650 form C
Mating Electrical Connectors Mating connector supplied as standard
Pura M12: Optional 0.8, 2, 5 meter (2.62, 6.56, 16.4 foot) M12 A coded connector/cable available
Diagnostic Conditions (factory programmed) Sensor fault: 23 mA
Under-range dew point: 4 mA
Over-range dew point: 20 mA
Approved Galvanic Isolators KFD2-CR-EX1.20200
KFD2-CR-EX1.30200
KFD0-CS-EX1.50P
KFD0-CS-EX2.50P
KFD2-STC4-EX1.H
MTL5041
MTL5040
Expand Table

* Applicable on digital Modbus RTU output only

Model Chart of Michell Pura

Monitor Technical Specifications

Product Pura Advanced Online 2 Pura Online
Online Range -120…-40 °Cdp (-184…-40 °Fdp)
Online Resolution 51/2 digit 4 digit
Auxiliary Pressure Input Maximum 24 MPa (240 barg / 3481 psig) Not available
Pressure Compensation Live 4…20 mA pressure transmitter or fixed programmable value Not available
Moisture Content Scales Automatic compensation for ppmV, lbs/MMscf, g/m3 units Dew-point and ppmV ranges available
Relay Alarm Type/Rating 2 x Form A, 2 x Form C 30 V DC 5A Namur compliant programmable relay outputs for process and fault conditions Alarm 1 relay: single pole make contact, rating 3 A @ 250 V AC
Alarm 2 relay: changeover contacts, rating 5 A @ 250 V AC
Sensor Input Signal Modbus RTU over RS485 4…20 mA
Online Output Signals (analog) 3 x 4…20 mA fully user-configurable and scalable 1 x 4…20 mA or 0…20 mA fully user-configurable and scalable
Online Output Signal (digital) Modbus RTU over RS485 Modbus RTU over RS485
Online Supply Voltage 85…265 V AC
18…28 V DC
85…265 V AC
24 V DC
Online Power Consumption AC Power: 7.5 VA
DC Current: 170 mA @ 24 V DC
60 mA max.
Electrical Safety BS/EN61010-1: 2010
Operating Temperature 0…+50 °C (+32…+122 °F)
Storage Temperature 0…+60 °C (+32…+140 °F) -10…+60 °C (+14…+140 °F)
Ingress Protection IP54 & NEMA Type 2 & 12K front panel only IP65 front panel
IP20 rear panel
Expand Table

 

User Guide and Instruction manual for Michell Pura

You can request the necessary certificates, documentation, instructions and user guide for Michell Pura using the special form.

You can buy Michell Pura in UAE at a price starting from По запросу $ in «Texair FZCO» by leaving a request on the website, by phone +441225535040 or by email . Michell Pura price are subject to change depending on exchange rates. We deliver instruments by transport companies in United Arab Emirates, Kuwait, Qatar, Saudi Arabia, Saudi Arabia, Bahrain and other Middle Eastern countries.

Generate an article by selecting the parameters below
Article:
Quantity:
-
+
Clear
I know the article / Need help
Get Offer
The article is not fully generated. Please double-check the selected values.